PRELIMINARY
RV5C386A
2) The second method to reading data from the internal register is to start reading immediately after writing
to the Internal Address Pointer and the Transmission Format Register. Although this method is not based
on I2C-Bus standard in a strict sense it still effective to shorten read time to ease load to the master. Set
4h to the transmission format register when this method used.
Example 2 of data read (when data is read from internal addresses Eh to 1h)
R/W=0(Write)
S 0 1 1 0 0 1 0 0 A1 1 1 0 0 1 0 0 A
Data
A
Slave Address
← (0110010)
Address Transmission
Pointer Format
←Eh Register←4h
Reading of data from
the internal address Eh
Data
A
Data
A
Data
/A P
Reading of data from Reading of data from Reading of data from
the internal address Fh the internal address 0h the internal address 1h
Master to slave
S Start Condition
A A /A Acknowledge Signal
Slave to Master
P Stop Condition
12345
- 23 -