Programming
Initialization and Controls
The CDP1851 PlO must be cleared by a low on the CLEAR
input during power-on to set it for programming. Once
programmed, modes can be changed without clearing
except when exiting the bit-programmable mode. A low on
the CLEAR input sets both ports to the input modes,
disables interrupts, unmasks all bit-programmed interrupt
bits, and resets the status register, A RDY, and B RDY.
Mode Setting
The control register must be sequentially loaded with the
appropriate mode set control bytes in order as shown in Table
1 (i.e. input mode then output mode, etc.). Port A is set with
the SET A bit = 1 and port B is set with the SET B bit = 1. If a
port is set to the bit-programmable mode, the bit-programming
control byte from Table 2 must be loaded. A bit is programmed
for output with the I/O bit = 1 and for input with the I/O bit = 0.
The STROBE and RDY lines may be programmed for input or
output with the STROBE/RDY control byte of Table 2. Input
data on the STROBE and RDY lines is detected by reading
the status register. When using the STROBE or RDY lines for
output, the control byte must be loaded every time output data
is to be changed. To program logical conditions that will gen-
erate an interrupt, the interrupt control byte of Table 3 must be
loaded. An interrupt mask of the eight I/O lines may be loaded
next, if bit D4 (mask follows) of the interrupt control byte = 1.
The I/O lines are masked if the corresponding bit of the inter-
rupt mask register is 1, otherwise it is monitored. Any combi-
nation of masked bits are permissible, except all bits masked
(mask = FF).
INT Enable Disable
To enable or disable the INT line in all modes, the interrupt
ENABLE/DISABLE byte must be loaded (see Table 4). Inter-
rupts can also be detected by reading the status register
(see Table 5). All interrupts should be disabled when
programming or false interrupts may occur. The INT outputs
are open drain NMOS devices that allow wired O Ring (use
10K pull-up registers).
GENERATE CLEAR PULSE
AT PIN 13
SET PORTS A AND B
TO INPUT, OUTPUT, OR
BIT-PROGRAMMABLE MODE
USING TABLE 1
REPEAT FOR EACH
BIT-PROGRAMMABLE
PORT
REPEAT FOR EACH
BIT-PROGRAMMABLE
PORT
IS
YES
EITHER PORT
SET TO THE
NO
BIT-PROGRAMMABLE
MODE 3
PERFORM FOLLOWING
SEQUENCE BEFORE
PROGRAMMING PORT A TO
BIDIRECTIONAL MODE
SET BIT DIRECTION
USING TABLE 2
WILL
INTERRUPTS
BE USED FOR
NO
BIT-PROGRAMMED
PORT?
NOW SET PORT A TO
BIDIRECTIONAL MODE,
IF DESIRED
SET MASTER INTERRUPT
ENABLE/DISABLE
USING TABLE 4
MAIN PROGRAM
YES
SET BIT LOGICAL
CONDITIONS AND
MASKING USING
TABLE 3
NOTES:
FIGURE 3. A FLOW CHART GUIDE TO CDP1851 MODE PROGRAMMING
1. STROBE/READY I/O Control Byte (Table 2) is also used to output data to STROBE and READY lines when bit-programmed.
2. Status register (Table 2) is used to input data from STROBE and READY lines when bit-programmed.
3. Interrupt status is also read from status register.