P4C163/163L
MAXIMUM RATINGS(1)
Symbol
Parameter
VCC
Power Supply Pin with
Respect to GND
VTERM
Terminal Voltage with
Respect to GND
(up to 7.0V)
TA
Operating Temperature
Value Unit
–0.5 to +7 V
–0.5 to
VCC +0.5
V
–55 to +125 °C
Symbol Parameter
TBIAS
Temperature Under
Bias
TSTG
Storage Temperature
PT
Power Dissipation
I
DC Output Current
OUT
Value Unit
–55 to +125 °C
–65 to +150 °C
1.0
W
50
mA
RECOMMENDED OPERATING TEMPERATURE AND SUPPLY VOLTAGE
Grade(2)
Military
Ambient
Temperature
–55 to +125°C
GND
0V
V
CC
5.0V ± 10%
Grade(2)
Commercial
Ambient
Temperature
0°C to +70°C
GND
0V
VCC
5.0V ± 10%
DC ELECTRICAL CHARACTERISTICS
Over recommended operating temperature and supply voltage(2)
Symbol
Parameter
VIH
VIL
VHC
VLC
VCD
VOL
V
OLC
VOH
VOHC
I
LI
Input High Voltage
Input Low Voltage
CMOS Input High Voltage
CMOS Input Low Voltage
Input Clamp Diode Voltage
Output Low Voltage
(TTL Load)
Output Low Voltage
(CMOS Load)
Output High Voltage
(TTL Load)
Output High Voltage
(CMOS Load)
Input Leakage Current
ILO
Output Leakage Current
Test Conditions
VCC = Min., IIN = –18 mA
IOL = +8 mA, VCC = Min.
P4C163
Min Max
2.2 VCC+0.5
–0.5(3)
0.8
VCC–0.2 VCC+0.5
–0.5(3)
0.2
–1.2
0.4
I
OLC
=
+100
µA,
V
CC
=
Min.
0.2
IOH = –4 mA, VCC = Min.
2.4
IOHC = –100 µA, VCC = Min.
VCC–0.2
V = Max.
CC
VIN = GND to VCC
Mil.
–10
+10
Com’l. –5
+5
VCC = Max., CE = VIH, Mil.
–10
+10
VOUT= GND to VCC
Com’l. –5
+5
P4C163L
Unit
Min Max
2.2 VCC+0.5 V
–0.5(3)
0.8
V
VCC–0.2 VCC+0.5 V
–0.5(3)
0.2
V
–1.2 V
0.4 V
0.2 V
2.4
V
VCC–0.2
V
–5
+5 µA
N/A
N/A
–5
+5 µA
N/A
N/A
CAPACITANCES(4)
(VCC = 5.0V, TA = 25°C, f = 1.0MHz)
Symbol Parameter Conditions Typ. Unit
CIN
Input Capacitance VIN = 0V
5 pF
Notes:
1. Stresses greater than those listed under MAXIMUM RATINGS may
cause permanent damage to the device. This is a stress rating only
and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification
is not implied. Exposure to MAXIMUM rating conditions for extended
periods may affect reliability.
Symbol
Parameter
Conditions Typ. Unit
COUT Output Capacitance VOUT = 0V 7 pF
2. Extended temperature operation guaranteed with 400 linear feet per
minute of air flow.
3. Transient inputs with VIL and IIL not more negative than –3.0V and
–100mA, respectively, are permissible for pulse widths up to 20 ns.
4. This parameter is sampled and not 100% tested.
110

Share Link: 