datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

74F193 Просмотр технического описания (PDF) - Philips Electronics

Номер в каталоге
Компоненты Описание
Список матч
74F193 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Philips Semiconductors
Up/down binary counter with separate up/down clocks
Product specification
74F193
FEATURES
Synchronous reversible 4-bit counting
Asynchronous parallel load capability
Asynchronous reset (clear)
Cascadable without external logic
DESCRIPTION
The 74F193 is a 4-bit synchronous up/down counter in the binary
mode. Separate up/down clocks, CPU and CPD respectively,
simplify operation. The outputs change state synchronously with the
Low-to-High transition of either clock input. If the CPU clock is
pulsed while CPD is held High, the device will count up. If CPD clock
is pulsed while CPU is held High, the device will count down. The
device can be cleared at any time by the asynchronous reset pin. It
may also be loaded in parallel by activating the asynchronous
parallel load pin.
Inside the device are four master-slave JK flip-flops with the
necessary steering logic to provide the asynchronous reset,
asynchronous preset, load, and synchronous count up and count
down functions.
Each flip-flop contains JK feedback from slave to master, such that a
Low-to-High transition on the CPD input will decrease the count by
one, while a similar transition on the CPU input will advance the
count by one.
One clock should be held High while counting with the other,
because the circuit will either count by twos or not at all, depending
on the state of the first JK flip-flop, which cannot toggle as long as
either clock input is Low. Applications requiring reversible operation
must make the reversing decision while the activating clock is High
to avoid erroneous counts.
The Terminal Count Up (TCU) and Terminal Count Down (TCD)
outputs are normally High. When the circuit has reached the
maximum count state of 15, the next High-to-Low transition of CPU
will cause TCU to go Low. TCU will stay Low until CPU goes High
again, duplicating the count up clock, although delayed by two gate
delays. Likewise, the TCD output will go Low when the circuit is in
the zero state and the CPD goes Low. The TC outputs can be used
as the clock input signals to the next higher order circuit in a
multistage counter, since they duplicate the clock waveforms.
Multistage counters will not be fully synchronous since there is a
two-gate delay time difference added for each stage that is added.
The counter may be preset by the asynchronous parallel load
capability of the circuit. Information present on the parallel Data
inputs (D0 - D3) is loaded into the counter and appears on the
outputs regardless of the conditions of the clock inputs when the
Parallel Load (PL) input is Low. A High level on the Master Reset
(MR) input will disable the parallel load gates, override both clock
inputs, and set all Q outputs Low. If one of the clock inputs is Low
during and after a reset or load operation, the next Low-to-High
transition of the clock will be interpreted as a legitimate signal and
will be counted.
TYPE
74F193
TYPICAL fMAX
125MHz
TYPICAL
SUPPLY CURRENT
(TOTAL)
32mA
ORDERING INFORMATION
DESCRIPTION
16-pin plastic DIP
COMMERCIAL RANGE
VCC = 5V ±10%,
Tamb = 0°C to +70°C
N74F193N
16-pin plastic SO
N74F193D
PKG DWG #
SOT38-4
SOT109-1
PIN CONFIGURATION
D1 1
Q1 2
Q0 3
CPD 4
CPU 5
Q2 6
Q3 7
GND 8
16 VCC
15 D0
14 MR
13 TCD
12 TCU
11 PL
10 D2
9 D3
SF00745
INPUT AND OUTPUT LOADING AND FAN-OUT TABLE
PINS
DESCRIPTION
74F(U.L.)
HIGH/LOW
D0 - D3
Data inputs
1.0/1.0
CPU
Count up clock input (active rising edge)
CPD
Count down clock input (active rising edge)
PL
Asynchronous parallel load control input (active Low)
1.0/3.0
1.0/3.0
1.0/1.0
MR
Asynchronous master reset input
1.0/1.0
Q0 - Q3
Flip-flop outputs
50/33
TCU
Terminal count up (carry) output (active Low)
50/33
TCD
Terminal count down (borrow) output (active Low)
50/33
NOTE: One (1.0) FAST Unit Load (U.L.) is defined as: 20µA in the High state and 0.6mA in the Low state.
LOAD VALUE
HIGH/LOW
20µA/0.6mA
20µA/1.8mA
20µA/1.8mA
20µA/0.6mA
20µA/0.6mA
1.0mA/20mA
1.0mA/20mA
1.0mA/20mA
1995 Jul 17