3.2 OSCILLATOR SAFEGUARD
The L9805 contains an oscillator safe guard func-
tion.
This function provides a real time check of the
crystal oscillator generating a reset condition when
the clock frequency has anomalous value.
If fOSC<flow, a reset is generated.
If fOSC>fhigh, a reset is generated.
A flag in the Dedicated Control Status Register in-
dicates if the last reset is a safeguard reset.
At the output of reset state the safeguard is disa-
ble. To activate the safeguard SFGEN bit must be
set.
Notes: Following a reset, the safeguard is disa-
bled. Once activated it cannot be disabled, except
by a reset.
3.2.1 Dedicated Control Status Register
DCSR
Address 0022h - Read/Write
Reset Value:xx00 0000 (00h)
SGFL
SGFH
SFGEN
CANDS
b
3
b
2
b
1
PIEN
b6 = SGFH: Safeguard high flag. Set by an Oscil-
lator Safeguard Reset generated for frequency too
high, cleared by software (writing zero) or Power
On / Low Voltage Reset. This flag is useful for dis-
tinguishing Safeguard Reset, Power On / Low
Voltage Reset and Watchdog Reset.
b7 = SGFL: Safeguard low flag. Set by an Oscilla-
tor Safeguard Reset generated for frequency too
low, cleared by software (writing zero) or Power
On / Low Voltage Reset. This flag is useful for dis-
tinguishing Safeguard Reset, Power On / Low
Voltage Reset and Watchdog Reset.
b5 = SFGEN: Safeguard enable when set. It’s
cleared only by hardware after a reset.
b4 = CANDS: CAN Transceiver disable. When this
bit is set the CAN transceiver goes in Power Down
Mode and does not work until this bit is reset.
CANDS is 0 after reset so the standard condition is
with the transceiver enabled. This bit can be used
by application requiring low power consumption
(see Section 5.7 for details).
b3,b2,b1 = not used
b0 = PIEN: PWMI input enable. When set, the
PWMI input line is connected to Input Capture 2 of
Timer 2. Otherwise, ICAP2_2 is the alternate func-
tion of PA7. See Figure 31 for the explanation of
this function.
16/103