datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

RS5C372A-E2 Просмотр технического описания (PDF) - RICOH Co.,Ltd.

Номер в каталоге
Компоненты Описание
Список матч
RS5C372A-E2 Datasheet PDF : 59 Pages
First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
RS5C372A/B
2.7-6 Alarm_B day-of-the-week register (internal address Dh)
D7
D6
D5
D4
D3
D2
D1
D0
BW6
BW5
BW4
BW3
BW2
BW1
BW0 (For write operation)
0
BW6
BW5
BW4
BW3
BW2
BW1
BW0 (For read operation)
0
Undefined Undefined Undefined Undefined Undefined Undefined Undefined Default*
*) The default means read value when XSTP bit is set to “1” by starting up from 0V, or supply voltage drop, etc.
· Alarm_A, Alarm_B hour register D5 is set to 0 for AM and 1 for PM in the 12-hour display system at AP/A.
The register D5 indicates 10 digit of hour digit in 24-hour display system at AH20.
· To activate alarm operation, any imaginary alarm time setting should not be left to avoid unmatching.
· In hour digit display midnight is set to 12, noon is set to 32 in 12-hour display system. (See section 2.2-1)
· AW0 to AW6 correspond to the day-of-the-week counter (W4, W2, W1) being set at (0, 0, 0) to (1, 1, 0).
· No alarm pulses are output when all of AW0 to AW6 are set to “0”.
Example of Alarm Time Settings
Day-of-the-week
12-hour system
24-hour system
Alarm Time Settings
Sun. Mon. Tue. Wed. Thu. Fri. Sat.
10-hour 1-hour 10-min 1-min 10-hour 1-hour 10-min 1-min
AW0 AW1 AW2 AW3 AW4 AW5 AW6
00:00 AM every day
111111112000000
01:30 AM every day
111111101300130
11:59 AM every day
111111111591159
00:00 PM on
011111032001200
Monday through Friday
01:30 PM on Sunday
100000021301330
11:59 PM on Monday,
010101031592359
Wednesday, and Friday
Designation of days of the week and AW0 to AW6 in the above table is an example.
25