IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
PROGRAMMING FLAG OFFSETS
Full and Empty Flag offset values are user programmable. The
IDT72261LA/72271LA has internal registers for these offsets. Default
settings are stated in the footnotes of Table 1 and Table 2. Offset values
can be programmed into the FIFO in one of two ways; serial or parallel
loading method. The selection of the loading method is done using the LD
(Load) pin. During Master Reset, the state of the LD input determines
whether serial or parallel flag offset programming is enabled. A HIGH on
LD during Master Reset selects serial loading of offset values and in
addition, sets a default PAE offset value of 3FFH (a threshold 1,023 words
from the empty boundary), and a default PAF offset value of 3FFH (a
threshold 1,023 words from the full boundary). A LOW on LD during Master
Reset selects parallel loading of offset values, and in addition, sets a
default PAE offset value of 07FH (a threshold 127 words from the empty
boundary), and a default PAF offset value of 07FH (a threshold 127 words
from the full boundary). See Figure 3, Offset Register Location and Default
Values.
In addition to loading offset values into the FIFO, it also possible to read
the current offset values. It is only possible to read offset values via parallel
read.
Figure 4, Programmable Flag Offset Programming Sequence, summa-
rizes the control pins and sequence for both serial and parallel program-
ming modes. For a more detailed description, see discussion that follows.
The offset registers may be programmed (and reprogrammed) any time
after Master Reset, regardless of whether serial or parallel programming
has been selected.
TABLE 1 — STATUS FLAGS FOR IDT STANDARD MODE
Number of
Words in
FIFO
IDT72261LA
0
1 to n (1)
(n+1) to 8,192
8,193 to (16,384-(m+1))
(16,384-m) (2) to 16,383
16,384
IDT72271LA
0
1 to n (1)
(n+1) to 16,384
16,385 to (32,768-(m+1))
(32,768-m) (2) to 32,767
32,768
FF PAF HF PAE EF
H HH L L
H HH L H
H HH H H
H HL H H
H LL H H
L LL H H
NOTES:
1. n = Empty Offset, Default Values: n = 127 when parallel offset loading is selected or n = 1,023 when serial offset loading is selected.
2. m = Full Offset, Default Values: m = 127 when parallel offset loading is selected or m = 1,023 when serial offset loading is selected.
TABLE 2 — STATUS FLAGS FOR IDT STANDARD MODE
IDT72261LA
IDT72271LA
IR PAF HF PAE OR
0
0
L HH LH
Number of
Words in
FIFO (1)
1 to n+1(1)
(n+2) to 8,193
8,194 to (16,385-(m+1)) (2)
(16,385-m) to 16,384
16,385
1 to n+1(1)
(n+2) to 16,385
16,386 to (32,769-(m+1)) (2)
(32,769-m) to 32,768
32,769
L HH L L
L HH H L
L HL H L
LLL HL
HL L H L
NOTES:
1. n = Empty Offset, Default Values: n = 127 when parallel offset loading is selected or n = 1,023 when serial offset loading is selected.
2. m = Full Offset, Default Values: m = 127 when parallel offset loading is selected or m = 1,023 when serial offset loading is selected.
4671 drw 05