n Operation of IPGA
[Writing operation at ALC Enable]
Writing to IPGA6-0 bit is ignored during ALC operation and FADEIN/OUT operation.
[Writing operation at ALC Disable]
When writing to the control register continually, the control register should be written by an interval
more than zero crossing timeout. If not, there is a possibility that each IPGA of L/R channels has a different gain.
[IPGA Gain after completing ALC operation]
The IPGA gain changed by ALC operation. The actual gain of IPGA is changed during ALC operation but the IPGA
register doesn’t change. Therefore, when completing ALC operation (ALC bit; “1” à “0”), the IPGA register is different
from the actual gain of IPGA. The value should be written to the IPGA register in order to set the actual gain of IPGA
with a register value.
[Operation of IPGA at power-down by the control register]
IPGA gain is reset when PM0 bit is “0”, and then IPGA operation starts from the default value when PM0 bit is changed
to “1”. When IPGA6-0 bits are read, the register values written by the last write operation are read out regardless the
actual gain.
n Control Register R/W Timing
The data on the 4 wires serial interface consists of op-code (3bit), address (LSB-first, 5bit) and control data (LSB-first,
8bit). The transmitting data is output to each bit by “↓” of CCLK, the receiving data is latched by “↑” of CCLK. Writing
data becomes effective by “↑” of CSN. Reading data becomes Hi-z (Floating) by “↑” of CSN. CSN should be held to “H”
at no access. In case of connecting between CDTI and CDTO, the I/F can be also contolled by 3-wires.
CCLK always needs 16 edges of “↑” during CSN = “L”. Reading/Writing of the address except 00H ∼
09H are inhibited. Reading/Writing of the control registers by except op0 = op1 = “1” are invalid.
CSN
CCLK
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CDTI
WRITE
CDTO
READ
CDTI
CDTO
op0 op1 op2 A0 A1 A2 A3 A4 D0 D1 D2 D3 D4 D5 D6 D7
“1” “1” “1”
Hi-Z
op0 op1 op2 A0 A1 A2 A3 A4
“1” “1” “0”
Hi-Z
D0 D1 D2 D3 D4 D5 D6 D7
Hi-Z
op0-op2: Op code (110:READ, 111:WRITE)
A0-A4: Register Address
D0-D7: Control data
Figure 16. Control Data Timing
MS0132-E-01
- 19 -