SPECIFICATIONS
VIN = VOUT + 0.4 V, VBIAS = 5 V, IOUT = 10 mA, CIN = 1 μF, COUT = 1 μF, CBIAS = 1 μF, TA = 25°C, unless otherwise noted.
Table 1.
Parameter
INPUT VOLTAGE RANGE
BIAS VOLTAGE RANGE
OPERATING SUPPLY CURRENT
BIAS OPERATING CURRENT
SHUTDOWN CURRENT
FIXED OUTPUT VOLTAGE ACCURACY
LINE REGULATION
LOAD REGULATION2
DROPOUT VOLTAGE3
START-UP TIME4
CURRENT LIMIT THRESHOLD5
THERMAL SHUTDOWN
Thermal Shutdown Threshold
Thermal Shutdown Hysteresis
EN INPUT
EN Input Logic High
EN Input Logic Low
EN Input Leakage Current
UNDERVOLTAGE LOCKOUT
Input Voltage Rising
Input Voltage Falling
Hysteresis
Symbol
VIN
VBIAS
IVIN 1
IBIAS
ISD-VIN
ISD-VBIAS
VOUT
∆VOUT/∆VIN
∆VOUT/∆IOUT
VDROPOUT
TSTART-UP
ILIMIT
TSSD
TSSD-HYS
VIH
VIL
VI-LEAKAGE
UVLO
UVLORISE
UVLOFALL
UVLOHYS
Conditions
TJ = −40°C to +125°C
TJ = −40°C to +125°C
IOUT = 0 μA
IOUT = 0 μA, TJ = −40°C to +125°C
IOUT = 1 mA
IOUT = 1 mA, TJ = −40°C to +125°C
IOUT = 100 mA
IOUT = 100 mA, TJ = −40°C to +125°C
IOUT = 350 mA
IOUT = 350 mA, TJ = −40°C to +125°C
TJ = −40°C to +125°C
EN = GND
EN = GND, TJ = −40°C to +85°C
EN = GND, TJ = +85°C to +125°C
EN = GND
EN = GND, TJ = −40°C to +125°C
IOUT = 10 mA
1 mA < IOUT < 350 mA, VIN = (VOUT + 0.4 V) to 3.6 V
1 mA < IOUT < 350 mA, VIN = (VOUT + 0.4 V) to 3.6 V,
TJ = −40°C to +125°C
VIN = (VOUT + 0.4 V) to 3.6 V, TJ = –40°C to +125°C
IOUT = 10 mA to 350 mA
IOUT = 10 mA to 350 mA, TJ = −40°C to +125°C
IOUT = 10 mA, VBIAS = 2.3 V, VOUT = 3 V
IOUT = 10 mA, VBIAS = 2.3 V, VOUT = 3 V,
TJ = −40°C to +125°C
IOUT = 100 mA, VBIAS = 2.3 V, VOUT = 3 V
IOUT = 100 mA, VBIAS = 2.3 V, VOUT = 3 V,
TJ = −40°C to +125°C
IOUT = 350 mA, VBIAS = 2.3 V, VOUT = 3 V
IOUT = 350 mA, VBIAS = 2.3 V, VOUT = 3 V,
TJ = −40°C to +125°C
VOUT = 1.2 V
TJ rising
2.3 V ≤ VBIAS ≤ 5.5 V
2.3 V ≤ VBIAS ≤ 5.5 V
EN = BIAS or GND
EN = BIAS or GND, TJ = −40°C to +125°C
TJ = −40°C to +125°C
TJ = −40°C to +125°C
Min Typ Max Unit
1.2
3.6 V
2.3
5.5 V
25
μA
44
μA
40
μA
58
μA
100
μA
130 μA
160
μA
220 μA
16
μA
28
μA
0.1
μA
1.0 μA
20
μA
0.1
μA
1.0 μA
−1
+1
%
−2
+2
%
−3
+3
%
−0.10
+0.10 %/ V
0.001
%/A
0.005 %/A
2
mV
3.5 mV
17
mV
28
mV
70
mV
100 mV
200
μs
400 550 1000 mA
150
°C
15
°C
1.2
V
0.4 V
0.1
μA
1
μA
2.1 V
1.5
V
180
mV
Rev. 0 | Page 3 of 20