datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

ADM2486BRW Просмотр технического описания (PDF) - Analog Devices

Номер в каталоге
Компоненты Описание
Список матч
ADM2486BRW Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ADM2486
ADM2486 CHARACTERISTICS
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-Output)1
Capacitance (Input-Output)1
Input Capacitance2
Input IC Junction-to-Case Thermal Resistance
Output IC Junction-to-Case Thermal Resistance
Symbol
RI-O
CI-O
CI
θJCI
θJCO
Min Typ Max Unit Test Conditions
1012
3
pF
f = 1 MHz
4
pF
33
°C/W Thermocouple located at
28
°C/W center of package underside
1 Device considered a 2-terminal device: Pins 1, 2, 3, 4, 5, 6, 7, and 8 shorted together, and Pins 9, 10, 11, 12, 13, 14, 15, and 16 shorted together.
2 Input capacitance is from any input data pin to ground
REGULATORY INFORMATION
The ADM2486 has been approved by the following organizations:
Table 5.
Organization
UL
Approval Type
Recognized under 1577 component recognition program.
File E214100
CSA
Approved under CSA Component Acceptance Notice #5A. File 205078.
VDE
Certified according to DIN EN 60747-5-2 (VDE 0884 Part 2): 2003-01
Complies with DIN EN 60747-5-2 (VDE 0884 Part 2): 2003-01,
DIN EN 60950 (VDE 0805): 2001-12; EN 60950: 2000
File 2471900-4880-0001
Notes
In accordance with UL1577, each ADM2486
is proof tested by applying an insulation
test voltage ≥3000 V rms for 1 sec (current
leakage detection limit = 5 µA).
In accordance with VDE 0884, each ADM2486
is proof tested by applying an insulation
test voltage ≥1050 VPEAK for 1 sec
(partial discharge detection limit = 5 pC).
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Symbol Value
Rated Dielectric Insulation Voltage
2500
Minimum External Air Gap (Clearance)
L(I01)
7.45 min
Unit
V rms
mm
Minimum External Tracking (Creepage)
L(I02)
8.1 min
mm
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index) CTI
Isolation Group
0.017 min mm
>175
V
IIIa
Conditions
1-minute duration.
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance along body.
Insulation distance through insulation.
DIN IEC 112/VDE 0303 Part 1.
Material Group (DIN VDE 0110, 1/89, Table 1).
Rev. C | Page 7 of 20

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]