datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

FCT162511AT(2001) Просмотр технического описания (PDF) - Integrated Device Technology

Номер в каталоге
Компоненты Описание
Список матч
FCT162511AT
(Rev.:2001)
IDT
Integrated Device Technology IDT
FCT162511AT Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
IDT54/74FCT162511AT/CT
FAST CMOS 16-BIT REGISTERED/LATCHED TRANSCEIVER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
SWITCHING CHARACTERISTICS OVER OPERATING RANGE (SET UP TIMES)
FCT162511AT
FCT162511CT
Symbol
Parameter
Test Conditions(1, 3)
Ind.
Mil.
Ind.
Mil.
Min. Max. Min. Max. Min. Max. Min. Max. Unit
tSU
Set-up Time
GEN/CHK LOW
PBx valid
CL = 50pF 4 — 4 — 3 — 3.5 — ns
HIGH or LOW
PBx not valid
RL = 5003 — 3 — 3 — 3 — ns
Ax to CLKAB GEN/CHK HIGH
PERB valid
4 — 4 — 3 — 3 — ns
PERB not valid
3 — 3 — 3 — 3 — ns
tSU
Set-up Time
GEN/CHK HIGH
PERB valid
4 — 4 — 3 — 3 — ns
PAx to CLKAB
PERB not valid
3 — 3 — 3 — 3 — ns
tSU
Set-up Time
PERA valid
4 — 4 — 3 — 3 — ns
Bx to CLKBA,
PERA not valid
3 — 4 — 3 — 3 — ns
PBx to CLKBA
tSU
Set-up Time
CLKAB LOW
PBx valid
3.5 — 3.5 — 3 — 3 — ns
Ax to LEAB
GEN/CHK LOW
PBx not valid
3 — 3 — 3 — 3 — ns
CLKAB LOW
PERB valid
3.5 — 3.5 — 3 — 3 — ns
GEN/CHK HIGH
PERB not valid
3 — 3 — 3 — 3 — ns
CLKAB HIGH
PBx valid
3.5 — 3.5 — 3 — 3 — ns
GEN/CHK LOW
PBx not valid
3 — 3 — 3 — 3 — ns
CLKAB HIGH
PERB valid
3.5 — 3.5 — 3 — 3 — ns
GEN/CHK HIGH
PERB not valid
3 — 3 — 3 — 3 — ns
tSU
Set-up Time
CLKAB LOW
PERB valid
3.5 — 3.5 — 3 — 3 — ns
PAx to LEAB GEN/CHK HIGH
PERB not valid
3 — 3 — 3 — 3 — ns
CLKAB HIGH
PERB valid
3.5 — 3.5 — 3 — 3 — ns
GEN/CHK HIGH
PERB not valid
3 — 3 — 3 — 3 — ns
tSU
Set-up Time
CLKBA LOW
PERA valid
3.5 — 3.5 — 3 — 3 — ns
Bx to LEBA
PERA not valid
3 — 3 — 3 — 3 — ns
PBx to LEBA CLKBA HIGH
PERA valid
3.5 — 3.5 — 3 — 3 — ns
tSK(O)
Output Skew(4)
PERA not valid
3 — 3 — 3 — 3 — ns
— 0.5 — 0.5 — 0.5 — 0.5 ns
SWITCHING CHARACTERISTICS OVER OPERATING RANGE (HOLD TIMES)
Symbol
tH
tH
tH
tH
tH
tW
tW
Parameter
Hold Time HIGH or LOW Ax to LEAB, Bx to LEBA
Hold Time HIGH or LOW PAx to LEAB
Hold Time HIGH or LOW PBx to LEBA
Hold Time Ax to CLKAB, PAx to CLKAB
Hold Time Bx to CLKBA, PBx to CLKBA
LEAB or LEBA Pulse Width HIGH(2)
CLKAB or CLKBA Pulse Width HIGH or LOW(2)
Condition(1)
CL= 50pF
RL = 500
FCT162511AT
FCT162511CT
Ind.
Mil.
Ind.
Mil.
Min. Max. Min. Max. Min. Max. Min. Max. Unit
1 — 1 — 1 — 1 — ns
1 — 1 — 1 — 1 — ns
1 — 1 — 1 — 1 — ns
1 — 1 — 0 — 0 — ns
1 — 1 — 0 — 0 — ns
3 — 3 — 3 — 3 — ns
3 — 3 — 3 — 3 — ns
NOTES:
1. See test circuits and waveforms.
2. This parameter is guaranteed but not tested.
3. "Not valid" means the set-up time indicated is not sufficient to assure proper functioning of this output; however, the set-up time indicated will assure proper functioning of the
A to B or B to A port respective to the indicated direction.
4. Skew between any two outputs of the same package, switching in the same direction, excluding PERx in clocked mode, and Pxx (parity bits) and PERx in transparent/
latched mode. This parameter is guaranteed by design.
8