Ultra Small Mobile Phone Xenon Photoflash
Capacitor Charger with IGBT Driver
Applications Information
Transformer Design
1. The transformer turns ratio, N, determines the output voltage:
N = NS / NP
VOUT = 31.5 × N Vd ,
where 31.5 is the typical value of VOUTTRIP , and Vd is the for-
ward drop of the output diode.
2. The primary inductance, LPRIMARY, determines the on-time of
the switch:
ton = (–LPRIMARY / R ) × ln (1 – ISWlim × R /VIN) ,
where R is the total resistance in the primary current path (includ-
ing RSWDS(on) and the DC resistance of the transformer).
If VIN is much larger than ISWlim × R, then ton can be approxi-
mated by:
ton = ISWlim × LPRIMARY /VIN .
3. The secondary inductance, LSECONDARY, determines the off-
time of the switch. Given:
LSECONDARY / LPRIMARY = N × N , then
toff = (ISWlim / N) × LSECONDARY /VOUT
= (ISWlim × LPRIMARY × N) /VOUT .
The minimum pulse width for toff determines what is the mini-
mum LPRIMARY required for the transformer. For example, if
ILIM = 1.5 A, N = 10, and VOUT = 315 V, then LPRIMARY must
be at least 4.2 μH in order to keep toff at 200 ns or longer. These
relationships are illustrated in figure 6.
In general, choosing a transformer with a larger LPRIMARY results
in higher efficiency (because a larger LPRIMARY corresponds to
a lower switch frequency and hence lower switching loss). But
transformers with a larger LPRIMARY also require more windings
and larger magnetic cores. Therefore, a trade-off must be made
between transformer size and efficiency.
Leakage Inductance and Secondary Capacitance
The transformer design should minimize the leakage induc-
tance to ensure the turn-off voltage spike at the SW node does
not exceed the absolute maximum specification on the SW pin
(refer to the Absolute Maximum Ratings table). An achievable
minimum leakage inductance for this application, however, is
usually compromised by an increase in parasitic capacitance.
Furthermore, the transformer secondary capacitance should be
minimized. Any secondary capacitance is multiplied by N2 when
reflected to the primary, leading to high initial current swings
when the switch turns on, and to reduced efficiency.
VSW
VIN
ISW
ton
toff
Vr
Figure 6. Transformer Selection Relationships
tf
tneg
ISW
VIN
VSW