ABSOLUTE MAXIMUM RATINGS
Table 5.
Parameter
AVDD to AGND
DVDD to DGND
PVDD to AGND
DVDDIO to DGND
DVDDIO to AVDD
PVDD to DVDD
DVDDIO to PVDD
DVDDIO to DVDD
AVDD to PVDD
AVDD to DVDD
Digital Inputs Voltage to
DGND
Digital Outputs Voltage to
DGND
Analog Inputs to AGND
Maximum Junction
Temperature (TJ MAX)
Storage Temperature Range
Infrared Reflow Soldering
(20 sec)
Rating
4V
2.2 V
2.2 V
4V
−0.3 V to +0.3 V
−0.3 V to +0.3 V
−0.3 V to +2 V
−0.3 V to +2 V
−0.3 V to +2 V
−0.3 V to +2 V
DGND − 0.3 V to DVDDIO + 0.3 V
DGND − 0.3 V to DVDDIO + 0.3 V
AGND − 0.3 V to AVDD + 0.3 V
125°C
−65°C to +150°C
260°C
ADV7403
STRESS RATINGS
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
PACKAGE THERMAL PERFORMANCE
To reduce power consumption when using the part the user is
advised to turn off any unused ADCs .
The junction temperature must always stay below the
maximum junction temperature (TJ MAX) of 125°C. This
equation shows how to calculate the junction temperature:
TJ = TA Max + (θJA × WMax)
where:
TA Max = 85°C.
θJA = 30°C/W.
WMax = ((AVDD × IAVDD)+(DVDD × IDVDD)+ (DVDDIO ×
IDVDDIO) + (PVDD × IPVDD)).
THERMAL SPECIFICATIONS
Table 6.
Thermal Characteristics
Junction-to-Case Thermal Resistance
Junction-to-Ambient Thermal Resistance
Symbol Test Conditions
Typ
θJC
4-layer PCB with solid ground plane
7
θJA
4-layer PCB with solid ground plane (still air)
30
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the
human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Unit
°C/W
°C/W
Rev. SpA | Page 9 of 24