datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

ML7012-06 Просмотр технического описания (PDF) - LAPIS Semiconductor Co., Ltd.

Номер в каталоге
Компоненты Описание
Список матч
ML7012-06
LAPIS
LAPIS Semiconductor Co., Ltd. LAPIS
ML7012-06 Datasheet PDF : 23 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
FEDL7012-06-02
ML7012-06
Bit Map Register List :
S14
Bit Initial value
Function enabled by “0”
7
1
Answer mode
6
0
Not used
5
1
Tone dial
4
0
Pulse speed = 10pps
3
1
Makes the result code the number.
2
0
With the result code
1
1
No echo back
0
0
Not used
Function enabled by “1”
Originate mode
Not used
Pulse dial
Pulse speed = 20pps
Makes the result code the character
string.
No result code
With echo back
Not used
Command
A, D
T, P
&P
V
Q
E
S16
Bit Initial value
Function enabled by “0”
Function enabled by “1”
Command
7
0
Not used
Not used
6
0
Stops analog loop back self-diagnostic. Analog loop back self-diagnostic
&T8
5
0
Stops remote
self-diagnostic.
digital
loop
back Remote digital loop back self-diagnostic
&T7
4
0
Stops remote digital loop back test. Remote digital loop back test
&T6
3
0
Not used
Not used
2
0
Not used
Not used
1
0
Not used
Not used
0
0
Stops analog loop back test.
Analog loop back test
&T1
S21
Bit Initial value
Function enabled by “0”
Function enabled by “1”
command
7
0
Not used
Not used
6
0
Not used
Not used
5
0
CD signal is always ON.
CD signal is ON by carrier detection.
&C
4
3
1
0
0
0
&DO
0
1
&D1
1
0
&D2
1
1
&D3
&D
DTR Control
2
0
Not used
Not used
1
1
Auto re-train disabled
Auto re-train enabled
%E
0
0
Not used
Not used
S22
Bit Initial value
Function enabled by “0”
7
1
Pulse dial make ration = 39%
6
1
0
1
1
5
1
0
X0 0
X1 0
4
1
0
0
1
3
2
0
1
0
0
M0
0
1
M1
1
0
1
0
Not used
0
0
Not used
Function enabled by “1”
Pulse dial make ration = 33%
1
1
X2 1
X3 1
X4
0
1
M2
1
1
M3
Not used
Not used
Command
&P
X
Extended
command
M
17/23

Share Link: 