datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

R5509-42 Просмотр технического описания (PDF) - Hamamatsu Photonics

Номер в каталоге
Компоненты Описание
Список матч
R5509-42
Hamamatsu
Hamamatsu Photonics Hamamatsu
R5509-42 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
RELATED PRODUCTS
Exclusive cooler PC176TSCE005 and PC176TSCE006 for R5509-42, -72
PC176TSCE005 and PC176TSCE006 are exclusively de-
signed coolers for R5509-42 and -72 using liquid nitrogen.
The dark current of R5509-42 and -72 will be reduced drasti-
cally by cooling so that the PMT will be able to detect very
weak light.
The cooler housing is magnetically and electrostatically shiel-
ded excluding external noises to provide very stable and high
S/N ratio measurement.
Hamamatsu also provides the PC176TSCE006 cooler suitable
for a selfpressurized liquid nitrogen container.
IFEATURES
GTemperature controllable range: 0 to -100 °C
(R5509-42, -72 operating range shall be: -70 to -90 °C)
GExclusive socket assembly with load resistor select-
able circuit
GBuilt-in magnetic electrostatic shield
GBuilt-in warning buzzer for liquid nitrogen supply
shortage
ISPECIFICATIONS
Parameter
Coolant medium
Temperature Controllable Range
Cool-down Time
Liquid Nitrogen Consumption rate (Max.)
Dry Nitrogen
Gas Pressure
Consumption rate
Voltage Divider Current
Socket Assembly
-HV Connector
Signal Connector
Load Resistor
AC Input Voltage
Power Consumption
Operating Ambient Temperature
Weight
Cooling Unit
Controller and others
Components
PC176TSCE005
PC176TSCE006
Liquid Nitrogen Vaporization
0 °C to -100 °C (continuously adjustable)
Approx. 2 h (-80 °C setting)
0.75 L/h (-100 °C setting)
35 kPa
47 L (14.7 MPa)/100 h
158 µA (PMT Supply Voltage: -1750 V)
SHV-R
BNC-R
50 / 1 k/ 100 k/ 10 M/ Open
100 V to 120 V, 220 V to 240 V (50/60 Hz)
15 VA
Less than +30 °C
Approx. 6 kg
Approx. 11 kg
Approx. 11 kg
Cooling Unit, Controller, Solenoid Control Cable,
Cooling unit, Controller, Solenoid Control Cable, Flow
Solenoid Valve, 3/8" OD Rubber Tube,
Limit Valve, Solenoid Valve, Insulated Transfer
Insulated Transfer Hose, LN2 Transfer Head for Hose, Control Solenoid with Connecting Hose with
35 mm to 40 mm Neck OD LN2 Dewar
3/4-16UNF or PT 1/4 Screws in End
IDIMENSIONAL OUTLINE (Unit: mm)
Cooling unit
222
120
111
6-M3
CENTER OF
PHOTOCATHODE
PHOTOMULTIPLIER
TUBE
330
86
59
13
6-M3
PHOTOCATHODE* (3 × 8)
86
13
111 O-RING
PHOTO-
MULTIPLIER
TUBE
PHOTO-
CATHODE
LN2 OUT (IN) SOCKET ASSEMBLY
LN2 IN (OUT)
SIDE VIEW
-HV (SHV-R)
SIGNAL OUTPUT (BNC-R)
SOCKET ASSEMBLY
WINDOW FLANGE
EVACUATED
WINDOW
HOUSING FRONT
PANEL
85.7 114
66.7 152.4
LOAD RESISTOR
ADJUSTOR SWITCH
4-No.10-32 UNC-2B
4-M6
BOTTOM VIEW
* The socket assembly can be rotated by 90 degrees in order to match the shape of the input light.
TACCA0151EF