XE5692H Boot Command
The XE5692H allows a default command string to be automatically loaded into the modem on power-up or
modem reset. A series of commands loads the default command string in Hex form into the modem’s
EEPROM. The EEPROM has 256 bytes available for command storage.
The sequence to load the default commands into EEPROM must begin with the Boot command and end
with a double carriage return. All commands are loaded into the EEPROM in Hex form beginning with
address M0000. Up to 8 addresses may be loaded with each command in the sequence.
The following example uses a typical configuration for an embedded application. ATE0 disables command
echo; ATQ1 disabled modem responses, and ATS0=1 sets the modem to automatically answer on the first
ring. This sequence is loaded into the modem EEPROM with the Boot command using the command
sequence below. This places the modem into the desired configuration each time power is applied or the
modem is reset
Boot Command Sequence
Command
Description
AT:M0000,42,4F,4F,54,0D,41,54,45 Load characters “B,O,O,T,<CR>,A,T,E” in EEPROM
beginning at address M0000
AT:M0008,30,0D,41,54,51,31,0D,41 Load characters “0,<CR>,A,T,Q,1,<CR>,A” in
EEPROM beginning at address M0008
AT:M0010,54,53,30,3D,31,0D,0D,0D Load characters “T,S,0,=,1,<CR>,<CR>,<CR>” in
EEPROM beginning at address M0010
XE5692H AT Commands
An asterisk indicates the factory default
A - Answer Command -
D - Dial Command -
0-9, A-D, #, * = Dialing Digits
P = Pulse dial
T = Tone dial
W = Wait for dial tone
, = Pause for the duration of S8
! = Switch hook flash
; = Return to the command state
En - Command Echo
n=0 Do not echo commands
n=1 Enable command echo *
Hn - Switch Hook Control -
n=0 Switch hook relay opens
n=1 Switch hook relay closes
In - Modem Identification
Mn - Speaker Activity -
n=0 Speaker off *
n=1 Speaker on until carrier received
n=2 Speaker remains on
n=3 Speaker on after dialing until DCD active
On - On Line
n=0 Return On Line with no retrain *
n=1 Initiate retrain while returning On line.
n=2 Initiate rate renegotiation while returning
On line.
Qn - Responses
n=0 Send responses *
n=1 No Responses
Sr? - Interrogate Register -
Sr=n - Set Register Value -
S$ - List values of all S-Registers -