Applications
Table 4-10 Test mode installation bits
Control Bits
mode 1 mode 2
Mode
1
1
OPERATE:
Normal operation of PLL and RI Buffer in installed mode.
MFO pin has programmed level.
0
1
not used:
identical to OPERATE
1
0
Testmode RCNTOUT:
Charge pump is turned off. R-counter output at
multifunctional MFO pin.
0
0
Testmode NCNTOUT:
Charge pump is turned off. N-counter output at
multifunctional MFOMFO pin.
4.3 Special programming sequences
Fast wake-up programming:
When the circuit is connected to the supply voltage all registers are undefined. Due to
the fact that each counter is loading its new start value after it is decremented to „zero“,
the start-up time of the counters with the programmed values is too long for some
applications. If the device has previously been set to ALLOFF- or AMPRUN-mode (see
Table 5) afterwards is turned to operating mode ALLRUN, the counters are starting
immediatly with the preprogrammed start values. Therefore for fast startup after standby
the following data transfer sequence is recommended:
Table 4-11 Fast Wake Up Data Transfer Sequence
Step
Serial Data Transfer Sequence
1
Long Control Word: ’OPERATE’
2
Set A-/N-Counter: AMPRUN mode
3
Set R-Counter
4
Set A-/N-Counter, AMPRUN mode
5
Set A-/N-Counter, ALLRUN mode
Wireless Components
4-7