Quad, Serial 8-Bit DACs
with Rail-to-Rail Outputs
_______________Detailed Description
Serial Interface
At power-on, the serial interface and all DACs are
cleared and set to code zero. The serial data output
(DOUT) is set to transition on SCLK's rising edge.
The MAX509/MAX510 communicate with microproces-
sors through a synchronous, full-duplex, 3-wire inter-
face (Figure 1). Data is sent MSB first and can be
transmitted in one 4-bit and one 8-bit (byte) packet or
in one 12-bit word. If a 16-bit control word is used, the
first four bits are ignored. A 4-wire interface adds a line
for LDAC and allows asynchronous updating. The serial
clock (SCLK) synchronizes the data transfer. Data is
transmitted and received simultaneously.
Figure 2 shows a detailed serial interface timing.
Please note that the clock should be low if it is stopped
between updates. DOUT does not go into a high-
impedance state if the clock or CS is high.
Serial data is clocked into the data registers in MSB-
first format, with the address and configuration infor-
mation preceding the actual DAC data. Data is
clocked in on SCLK's rising edge while CS is low. Data
at DOUT is clocked out 12 clock cycles later, either at
SCLK's rising edge (default or mode 1) or falling edge
(mode 0).
Chip select (CS) must be low to enable the DAC. If CS
is high, the interface is disabled and DOUT remains
unchanged. CS must go low at least 40ns before the
first rising edge of the clock pulse to properly clock in
the first bit. With CS low, data is clocked into the
MAX509/MAX510's internal shift register on the rising
edge of the external serial clock. SCLK can be driven
at rates up to 12.5MHz.
CS
SCLK
DIN
DOUT
MODE 1
(DEFAULT)
DOUT
MODE 0
•••
•••
INSTRUCTION
EXECUTED
A1 A0 C1 C0
D7 D6 D5 D4 D3 D2 D1 D0
MSB
LSB
DACA
A1 A0 C1 C0 D7
D6 D5 D4 D3 D2 D1 D0
•••
A1
A1 A0 C1 C0
D7 D6 D5 D4 D3 D2 D1 D0
A1
MSB
LSB
DACD
•••
A1
A1 A0 C1 C0 D7
D6 D5 D4 D3 D2 D1 D0
A1
DATA FROM PREVIOUS DATA INPUT
DATA FROM PREVIOUS DATA INPUT
A1 A0 C1 C0 D7
D6 D5 D4 D3 D2 D1 D0
•••
A1
A1 A0 C1 C0 D7
D6 D5 D4 D3 D2 D1 D0
A1
Figure 1. MAX509/MAX510 3-Wire Interface Timing
_______________________________________________________________________________________ 9