3.500
3.000
2.500
2.000
1.500
1.000
0.500
0.000
-0.500
-1.000
-1.500
-2.000
-2.500
DS2422 Temperature Accuracy at 3V
DS2422
Max. ± 0.1°C uncertainty
Min. ±0.25°C uncertainty
Max. ±1°C uncertainty
Temperature (°C)
Min. ± 0.1°C uncertainty
Max. ±0.5°C uncertainty
Min. ±1°C uncertainty
Max. ±0.25°C uncertainty
Min. ±0.5°C uncertainty
"Uncertainty" refers to the uncertainty of the temperature measurement when performing the 2-point calibration trim
as described in the application note. These graphs assume 11-bit temperature conversion. The accuracy can be
improved further through software correction. See the application note referenced as "Note 18" on the previous
page for details.
5 of 48