DG9421, DG9422
Vishay Siliconix
SPECIFICATIONSa Single Supply 3 V
Parameter
Analog Switch
Symbol
Test Conditions
Unless Otherwise Specified
V+ = 3 V, V- = 0 V, VIN = 0.4 Vf
Limits
- 40 °C to 85 °C
Tempb Min.d Typ.c Max.d Unit
Analog Signal Rangee
VANALOG
Full
0
3
V
Drain-Source
On-Resistance
Switch Off
Leakage Currentg
RDS(on)
IS(off)
ID(off)
V+ = 2.7 V, V- = 0 V
IS = 5 mA, VD = 0.5, 2.2 V
V+ = 3.3 V, V- = 0 V
VS = 1, 2 V, VD = 2, 1 V
Room
Full
7.3
8.8
10.1
Ω
Room - 1
1
Full - 10
10
Room - 1
Full - 10
1
10
nA
Channel-On
Leakage Currentg
ID(on)
V+ = 3.3 V, V- = 0 V
VD = VS = 1, 2 V
Room - 1
1
Full - 10
10
Digital Control
Input Current, VIN Lowe
IIL
Input Current, VIN Highe
IIH
Dynamic Characteristics
VIN Under Test = 0.4 V
VIN Under Test = 2.4 V
Full
- 1 0.02
1
µA
Full
- 1 0.02
1
Turn-On Time
Turn-Off Time
tON
RL = 300 Ω, CL = 35 pF, VS = 1.5 V
Room
Full
tOFF
See Figure 2
Room
Full
90
110
125
ns
32
84
99
Charge Injectione
Q
Vg = 0 V, Rg = 0 Ω, CL = 1 nF
Room
31
pC
Off-Isolatione
OIRR
RL = 50 Ω, CL = 5 pF , f = 1 MHz
Room
- 60
dB
Source Off Capacitancee
CS(off)
Room
35
Drain Off Capacitancee
CD(off)
f = 1 MHz
Room
34
pF
Channel On Capacitancee
CD(on)
Room
77
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
g. Leakage parameters are guaranteed by worst case test conditions and not subject to test.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
Document Number: 70679