1 2 3 4 5 6 7 8 9 10 Next Last
AD8387
Parameter
VIDEO OUTPUT CHARACTERISTICS
Output Voltage Swing
Output Voltage—Grounded Mode
Data Switching Delay: t75
Data Switching Delay Skew: Δt75
INV Switching Delay: t86
INV Switching Delay Skew: Δt86
Output Current
Output Resistance
REFERENCE INPUTS
VRL Range
VRH Range
VRH to VRL Range1
VRH Input Resistance
VRL Input Current
VRH Input Current
RESOLUTION
DIGITAL INPUT CHARACTERISTICS
CLK Frequency
Data Setup Time: t1
XFR Setup Time: t3
Data Hold Time: t2
XFR Hold Time: t4
CLK High Time: t5
CLK Low Time: t6
CLK High Time: t7
CLK Low Time: t8
CIN
IIH
IIH TSW
IIH XFR
IIL
IIL TSW
IIL XFR
VIH
VIL
VTH
POWER SUPPLIES
DVCC, Operating Range
DVCC, Quiescent Current
AVCC, Operating Range
AVCC, Quiescent Current
OPERATING TEMPERATURE
Ambient Temperature Range, TA7
Ambient Temperature Range, TA7
Conditions
AVCC − VOH, VOL − AGND
VIDx = 5 V step
VIDx = 10 V step
VRH ≥ VRL
VRH ≥ VRL
To VRL
Binary Coding
TA MIN to TA MAX
CLK input duty cycle 40% to 60%
DSW = HIGH
DSW = LOW
DSW = HIGH
DSW = HIGH
DSW = LOW
DSW = LOW
Still air, TSW = LOW
200 lfm airflow, TSW = LOW
Min Typ Max
Unit
0.9 1.3
V
0.06 0.150
V
15.7
ns
4
ns
16.2
ns
4
ns
100
mA
28
Ω
5.25
AVCC − 4
V
VRL
VRL + 2.75 V
0
2.75
V
22
−44
μA
111
μA
12
Bits
110
MHz
85
MHz
0
ns
0
ns
3.5
ns
3.5
ns
2.5
ns
3.0
ns
3.5
ns
4.0
ns
3
pF
0.05
μA
333
μA
0.05
μA
−0.6
μA
−1.3
μA
−1.2
μA
2
V
0.8
V
1.65
V
3
3.3 3.6
V
54 70
mA
11
18
V
75 100
mA
0
75
°C
0
85
°C
1 VDE = differential error voltage, VCME = common-mode error voltage, ΔVDE = VDE matching between outputs, ΔV = maximum deviation between outputs, and full-scale output
voltage = VFS = 2 × (VRH − VRL). See the Accuracy section.
2 Guaranteed monotonic by characterization to four sigma limits.
3 Measured on two outputs differentially as CLK and DBx(0:11) are driven and XFR is held LOW.
4 Measured on two outputs differentially as the others are transitioning by 5 V. Measured for both states of INV.
5 Measured from 50% of rising CLK edge to 50% of output change. Measurement is made for both states of INV.
6 Measured from 50% of INV transition to 50% of output change.
7 Operation at elevated ambient temperature requires a thermally optimized PCB and additional thermal management, such as airflow across the surface of the AD8387.
Rev. 0 | Page 4 of 16