AD5666
Parameter
POWER REQUIREMENTS
VDD
A Grade1
B Grade1
Min Typ Max Min Typ Max
2.7
3.6 2.7
3.6
IDD (Normal Mode)4
VDD = 2.7 V to 3.6 V
VDD = 2.7 V to 3.6 V
IDD (All Power-Down Modes)5
VDD = 2.7 V to 3.6 V
0.65 0.85
1.3 1.5
0.2 1
0.65 0.85
1.3 1.5
0.2 1
1 Temperature range is −40°C to +105°C, typical at 25°C.
2 Linearity calculated using a reduced code range of 512 to 65,024. Output unloaded.
3 Guaranteed by design and characterization; not production tested.
4 Interface inactive. All DACs active. DAC outputs unloaded.
5 All four DACs powered down.
Unit
V
mA
mA
μA
Conditions/Comments
All digital inputs at 0 or VDD,
DAC active, excludes load current
VIH = VDD and VIL = GND
Internal reference off
Internal reference on
VIH = VDD and VIL = GND
Rev. A | Page 6 of 28