Quad 2-input multiplexer; 3-state
Table 7. Dynamic characteristics …continued
Voltages are referenced to GND (ground = 0 V); for test circuit see Figure 8.
Symbol Parameter Conditions
25 °C
40 °C to +85 °C 40 °C to +125 °C Unit
Min Typ[1] Max Min Max
Min
Max
74AHCT257; VCC = 4.5 V to 5.5 V
tpd
propagation nI0, nI1 to nY; see Figure 6 [2]
delay
CL = 15 pF
- 3.7 6.5 1.0
8.0
1.0
9.0 ns
CL = 50 pF
- 4.9 8.5 1.0 10.0
1.0
11.0 ns
S to nY; see Figure 6
[2]
CL = 15 pF
- 5.1 9.0 1.0 10.5
1.0
11.5 ns
CL = 50 pF
- 6.4 10.5 1.0 12.5
1.0
13.5 ns
ten
enable time OE to nY; see Figure 7
[3]
CL = 15 pF
- 3.9 8.0 1.0
9.0
1.0
10.0 ns
CL = 50 pF
- 5.1 10.0 1.0 11.0
1.0
12.0 ns
tdis
disable time OE to nY; see Figure 7
[4]
CL = 15 pF
- 4.5 7.5 1.0
8.0
1.0
8.5 ns
CL = 50 pF
- 6.5 9.5 1.0 10.5
1.0
11.5 ns
CPD
power
fi = 1 MHz; VI = GND to VCC [5]
dissipation
capacitance
4 outputs switching via
input S
- 51 -
-
-
-
-
pF
1 output switching via
input I
- 15 -
-
-
-
-
pF
[1] Typical values are measured at nominal supply voltage (VCC = 3.3 V and VCC = 5.0 V).
[2] tpd is the same as tPLH and tPHL.
[3] ten is the same as tPZL and tPZH.
[4] tdis is the same as tPLZ and tPHZ.
[5] CPD is used to determine the dynamic power dissipation (PD in µW).
PD = CPD × VCC2 × fi × N + Σ(CL × VCC2 × fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
Σ(CL × VCC2 × fo) = sum of the outputs.