2SK2085
Power vs. Temperature Derating
1.6
1.2
0.8
0.4
0
50
100
150
200
Ambient Temperature Ta (°C)
Maximum Safe Operation Area
10
3
1
0.3
0.1
0.03
Operation in DC
this area is
limited by R DS(on)
OpPeWra(1t=iso1hn01otmm)10ss010µsµs
0.01
0.003
Ta = 25°C
0.001
0.1 0.3 1 3 10
Drain to Source Voltage
30 100 200
V DS (V)
Typical Output Characteristics
5
6V
Pulse Test
8V 5V
4 10 V
4V
3
3.5 V
2
3V
1
2.5 V
VGS = 2 V
0
2
4
6
8 10
Drain to Source Voltage V DS (V)
Typical Transfer Characteristics
5
4 V DS = 10 V
Pulse Test
3
2
1
Tc = 25 °C
–25 °C
75 °C
0
1
2
3
4
5
Gate to Source Voltage V GS (V)
4