TB62202AFG
2. Logic unit A/B (C/D unit is the same as A/B unit)
Function
This circuit is used to input from the DATA pins micro−step current setting data and to transfer them to the
subsequent stage. By switching the SETUP pin, the data in the mixed decay timing table can be overwritten.
SETUP
DATA
CLK
STROBE
RESET
Micro-step current setting data logic circuit
16-bit shift register
Data input
selector
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16-bit latch
A unit side
TORQUE
× 2 bits
DECAY
× 2 bits
B unit side
CURRENT
× 4 bits
B unit side
PHASE
× 1 bit
B
MIXED
DECAY
TIMING
Output control
circuit
Current feedback circuit
D/A circuit Output control circuit
Note: The RESET and SETUP pins are pulled down in the IC by 10-kΩ resistor.
When not using these pins, connect them to GND. Otherwise, malfunction may occur.
3