LV23200T
Continued from preceding page.
No. Control block data
Description
(14)
Forced monaural
• Data to determine the output of output port STSW, controlling the forced stereo functions.
control data
“Data” = 0 : MONO
1 : STEREO
STSW
(15)
SD sensitivity
• Data to determine the output of output ports SDC, controlling the SD sensitivity
control data
“Data” = SDC0 : 0, SDC1 : 0 → SD sensitivity 1 = 50dBµV (Typ)
SDC0 : 0, SDC1 : 1 → SD sensitivity 2 = 52dBµV (Typ)
SDC
SDC0 : 1, SDC1 : 0 → SD sensitivity 3 = 57dBµV (Typ)
SDC0 : 1, SDC1 : 1 → SD sensitivity 4 = 62dBµV (Typ)
* Above data values indicate the difference of SD sensitivity levels and are reference values.
DO control data (serial data output) composition
(1) OUT mode
Address
DI 0 1 0 1 0 1 0 0
DO
Related data
Description of DO output data
No. Control block data
Description
(1)
Stereo and SD
• Data latching stereo and SD indicator conditions.
indicators
Latching made in the data output (OUT) mode.
control data
SDIND←Stereo indicator condition 0 : ST ON, 1 : ST OFF
STIND←SD indicator condition
0 : SD ON, 1 : SD OFF
STIND, SDIND
(2)
PLL unlock data
• Data latching the content of unlock detection circuit
UL←0 : At unlock
UL
1 : At lock or in the detection stop mode
(3)
IF counter,
• Data latching the content of IF counter (20-bit binary counter)
binary counter
C19←MSB of binary counter
C0 ←LSB of binary counter
C19 to C0
Related data
UL0
UL1
CTE
GT0
GT1
No.8301-12/17