256 × 36 × 2 Bidirectional FIFO
LH543601
ABSOLUTE MAXIMUM RATINGS 1
PARAMETER
Supply Voltage to VSS Potential
Signal Pin Voltage to VSS Potential 3
DC Output Current 2
Storage Temperature Range
Power Dissipation (Package Limit)
RATING
–0.5 V to 7 V
–0.5 V to VCC + 0.5 V
± 40 mA
–65oC to 150oC
2 Watts (Quad Flat Pack)
NOTES:
1. Stresses greater than those listed under ‘Absolute Maximum Ratings’ may cause
permanent damage to the device. This is a stress rating for transient conditions only.
Functional operation of the device at these or any other conditions outside those indicated
in the ‘Operating Range’ of this specification is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect reliability.
2. Outputs should not be shorted for more than 30 seconds. No more than one output should be
shorted at any time.
3. Negative undershoot of 1.5 V in amplitude is permitted for up to 10 ns, once per cycle.
OPERATING RANGE
SYMBOL
TA
VCC
VSS
VIL
VIH
PARAMETER
Temperature,
Ambient
Supply Voltage
Supply Voltage
Logic LOW
Input Voltage 1
Logic HIGH
Input Voltage
MIN MAX UNIT
0
70
oC
4.5 5.5 V
0
0
V
–0.5 0.8 V
2.2
Vcc +
0.5
V
NOTE:
1. Negative undershoot of 1.5 V in amplitude is permitted
for up to 10 ns, once per cycle.
FROM PORT
INTERNAL
15
DATA BUS
(OR CONTROL
GATE)
TO ASSOCIATED
INPUT BUFFER,
IF ANY (SEE NOTE)
NOTE: Output-only pins have no
associated input buffer.
DnA/B (OR FLAG)
543601-39
Figure 4. Structure of Series Resistor
Input/Output Interface
DC ELECTRICAL CHARACTERISTICS (Over Operating Range)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP MAX UNIT
ILI
Input Leakage Current
VCC = 5.5 V, VIN = 0 V To VCC
–10
10 µA
ILO
I/O Leakage Current
OE VIH, 0 V VOUT VCC
–10
10 µA
VOL
Logic LOW Output Voltage
IOL = 8.0 mA
0.4 V
VOH
Logic HIGH Output Voltage IOH = –8.0 mA
ICC
Average Supply Current 1, 2 Measured at fCC = max
2.4
V
180 280 mA
ICC2
Average Standby Supply
Current 1, 3
All Inputs = VIHMIN (Clocks idle)
13
25 mA
ICC3
Power-Down Supply
Current 1
All Inputs = VCC – 0.2 V (Clocks idle)
0.002 0.4 mA
ICC4
Power-Down Supply
Current 1, 3
All Inputs = VCC – 0.2 V
(Clocks at fcc = max)
6
10 mA
NOTES:
1. ICC, ICC2, ICC3, and ICC4 are dependent upon actual output loading, and ICC and ICC4 are also dependent on cycle rates. Specified values are
with outputs open (for ICC: CL = 0 pF); and, for ICC and ICC4, operating at minimum cycle times.
2. ICC (MAX.) using worst case conditions and data pattern. ICC (TYP.) using VCC = 5 V and and ‘average’ data pattern.
3. ICC2 (TYP.) and ICC4 (TYP.) using VCC = 5 V and TA = 25°C.