datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

IDT54FCT162344AT Просмотр технического описания (PDF) - Integrated Device Technology

Номер в каталоге
Компоненты Описание
Список матч
IDT54FCT162344AT
IDT
Integrated Device Technology IDT
IDT54FCT162344AT Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
IDT54/74FCT162344AT/CT/ET
FAST CMOS ADDRESS LINE DRIVER
MILITARY AND COMMERCIAL TEMPERATURE RANGES
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Commercial: TA = –40°C to +85°C, VCC = 5.0V ± 10%; Military: TA = –55°C to +125°C, VCC = 5.0V ± 10%
Symbol
VIH
Parameter
Input HIGH Level
Test Conditions(1)
Guaranteed Logic HIGH Level
Min. Typ.(2) Max. Unit
2.0 —
V
VIL
II H
II L
IOZH
IOZL
VIK
IOS
VH
ICCL
ICCH
ICCZ
Input LOW Level
Input HIGH Current (Input pins)(5)
Input HIGH Current (I/O pins)(5)
Input LOW Current (Input pins)(5)
Input LOW Current (I/O pins)(5)
High Impedance Output Current
(3-State Output pins)(5)
Clamp Diode Voltage
Short Circuit Current
Input Hysteresis
Quiescent Power Supply Current
Guaranteed Logic LOW Level
VCC = Max.
VI = VCC
VI = GND
VCC = Max.
VO = 2.7V
VO = 0.5V
VCC = Min., IIN = –18mA
VCC = Max., VO = GND(3)
VCC = Max., VIN = GND or VCC
0.8
V
±1 µA
±1
±1
±1
±1 µA
±1
0.7 1.2 V
–80 140 225 mA
— 100 mV
5
500 µA
3069 lnk 05
OUTPUT DRIVE CHARACTERISTICS
Symbol
IODL
Parameter
Output LOW Current
Test Conditions(1)
VCC = 5V, VIN = VIH or VIL, VOUT = 1.5V(3)
Min. Typ.(2) Max. Unit
60 115 200 mA
IODH
Output HIGH Current
VCC = 5V, VIN = VIH or VIL, VOUT = 1.5V(3)
–60 –115 –200 mA
VOH
Output HIGH Voltage
VCC = Min.
VIN = VIH or VIL
IOH = –16mA MIL.
2.4 3.3 —
V
IOH = –24mA COM'L.
VOL
Output LOW Voltage
VCC = Min.
VIN = VIH or VIL
IOL = 16mA MIL.
IOL = 24mA COM'L.
— 0.3 0.55
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at Vcc = 5.0V, +25°C ambient.
3. Not more than one output should be tested at one time. Duration of the test should not exceed one second.
4. Duration of the condition can not exceed one second.
5. The test limit for this parameter is ± 5µA at TA = –55°C.
V
3069 lnk 06
5.6
4

Share Link: 