S/UNI-ATLAS
DATASHEET
PMC-1971154
ISSUE 7
PM7324 S/UNI-ATLAS
S/UNI-ATM LAYER SOLUTION
Egress functionality includes programmable direct lookup function, OAM-PM termination,
generation and monitoring, per-connection CLP0 and CLP1 cell counts (programmable) and
OAM-FM termination, generation and alarm generation (monitoring). An egress per-PHY
output buffering scheme resolves the head-of-line blocking issue.
UPC/NPC function is a programmable dual leaky bucket policing device with a programmable
action (tag, discard, or count only) for each bucket. A total of 3 programmable 16 bit non-
compliant cell counts are provided. The non-compliant cell counts may be programmed to
count, for example, dropped CLP0 cells, dropped CLP1 cells, and tagged CLP0 cells. The
UPC/NPC function also has a continuously violating mode, where a programmable action is
taken on all cells regardless of their compliance. AAL5 partial packet discard is also provided
so that the remainder of an AAL5 packet can be tagged or discarded if a single cell in the
packet is tagged or discarded as a result of violating policing.
In addition to the per-connection dual leaky bucket, a single leaky bucket UPC/NPC function is
provided on a per-PHY basis. A programmable action (tag, discard or count only) may be
configured for each PHY policing device. Three programmable non-compliant cell counts are
provided for each PHY. The non-compliant cell counts may be programmed to count, for
example, dropped CLP0 cells, dropped CLP1 cells and tagged CLP0 cells. The per-PHY
policing parameters and non-compliant cell counts are maintained in an on-chip RAM that can
be programmed and read via the 16-bit general purpose microprocessor interface.
Guaranteed Frame Rate frame-based policing selectable on a per-connection basis.
OAM-Performance monitoring is provided in the ingress and egress direction for bi-directional
PM sessions. A maximum of 512 (256 bi-directional sessions) PM sessions may be
simultaneously active. PM is supported on the F4 and F5 levels. The S/UNI-ATLAS provides
for the generation of Forward Monitoring and Backward Reporting PM cells (both segment
and end-to-end), the termination of Forward Monitoring and Backward Reporting cells, and for
non-intrusive monitoring of Forward Monitoring and Backward Reporting cells. The following
statistics are collected when terminating or monitoring PM flows:
1. Forward Impaired Block.
2. Forward Lost/Misinserted Impaired Block
3. Forward Severely Errored Cell Block (Lost).
4. Forward Severely Errored Cell Block (Misinserted).
5. Forward Severely Errored Cell Block (BIP-16 violations).
6. Forward Severely Errored Cell Block Combined (non-saturating)
7. Forward Lost CLP0+1 cell count.
8. Forward Lost CLP0 cell count.