EtronTech
EM564081
DC Characteristics (Ta = -40°C to 85°C, VDD = 2.3V to 3.6V)
Parameter Symbol
Test Conditions
Min Typ* Max Unit
Input low current IIL IIN = 0V to VDD
-1
−
Output low
voltage
Output high
voltage
VOL IOL = 2.1 mA
VOH IOH = -1.0 mA
-
−
VDD -
0.15
−
VDD = 3.6 V −
15
IDD1
Operating current
CE1# = VIL and
CE2 = VIH and
Cycle time
= min
VDD = 2.7 V
−
10
IOUT = 0mA
VDD = 2.3 V −
7
IDD2
Other Input = VIH / VIL
Cycle time = 1µs
−
−
IDDS1 CE1# = VIH or CE2 = VIL
−
−
Standby current IDDS2** CE1# = VDD – 0.2V or
(Note) CE2 = 0.2V
VDD = 3.6 V −
-70/85 VDD = 2.7 V −
VDD = 2.3 V −
1
0.8
0.5
Notes:
-70E/85E VDD = 3.6 V −
5
* Typical value are measured at Ta = 25°C.
** In standby mode with CE1# ≥ VDD - 0.2V, these limits are assured for the condition
CE2 ≥ VDD - 0.2V or CE2 ≤ 0.2V.
1 µA
0.4 V
−V
25
15
mA
12
5
0.5 mA
10
5 µA
3
80
Capacitance (Ta = 25°C; f = 1 MHz)
Parameter
Symbol Min Typ Max Unit Test Conditions
Input capacitance
CIN
−
−
10 pF
VIN = GND
Output capacitance COUT
−
−
10 pF
VOUT = GND
Notes: This parameter is periodically sampled and is not 100% tested.
Preliminary
4
Rev 0.7
January 2001