datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

CLS-391 Просмотр технического описания (PDF) - Unspecified

Номер в каталоге
Компоненты Описание
Список матч
CLS-391
ETC
Unspecified ETC
CLS-391 Datasheet PDF : 3 Pages
1 2 3
Limit Switchs
CLS Limit switch
Features
--------------------------------------------------------------------------------------------------------------
Economical & plastic type
Stainless steel roller, punch and spring
Swing amplitude, extra large 95°
PG13.5 cable gland that can be equipped.
Electrical life
Specifications
Model
CLS
Operating force
Release force
Pre-travel
Tripping position
Movement differential
Over travel
Total travel
Rotary indexing
OF Max
RF Min
PT Max
TP ± 10%
MD Max
OT Min
TT Min
Characteristics
Double Break Mechanism
Rated Voltage / Current
Contact Resistance
Insultation Resistance
Dielectric Strength
Electrical Life
Mechanical Life
Operating Speed
Degree of Protection
Ambient Temperature Rised
Conformed Standards
Operating Temperature
Storage Temperature
Ambient Operating Humdity
Shock Resistance
Vibration Frequency
Terminal Screw Torsional Force
Other Screw Torsional Force
Bare Wire Diameter
Cable Diameter
101
301
700g
200g
1.8mm
2.0mm
1.2mm
4.0mm
5.8mm
103
303
700g
200g
1.8mm
2.0mm
1.2mm
4.0mm
5.8mm
111
311
700g
200g
1.8mm
2.0mm
1.2mm
4.0mm
5.8mm
121
321
500g
100g-cm
20°
22.5°
10°
75°
95°
22.5°
127
327
700g
200g
1.8mm
2.0mm
1.2mm
4.0mm
5.8mm
131
331
500g-cm
100g-cm
20°
22.5°
10°
75°
95°
22.5°
161
361
100g
40g
30mm
22.5°
14°
20mm
50mm
171
371
100g
40g
30mm
22.5°
14°
20mm
50mm
181
381
100g
40g
30mm
22.5°
14°
20mm
50mm
191
391
500g-cm
100g-cm
20°
22.5°
10°
75°
95°
INO+INC Force Break snap action
10(4)A, 125, 250VAC / 6(2)A, 380VAC For inductance Load, Cos =Φ0.4
25mΩmax. (initial value)
100mΩmin. (at 500VDC)
1000VAC, 50/60 HZ for 1 minute between terminals of the same polarity
1500VAC, 50/60 HZ for 1 minute between current-carrying and non-current-carrying metal parts
1500VAC, 50/60 HZ for 1 minute between each terminal and ground
500,000 at 10A 250VAC Resistive
10, 000, 000 operations min. (under rated conditions)
5mm/s to 0.5m/s
IP65
Max 30over ambient temperature at rated voltage/current
Cenelec EN 50041, EN 50047, IEC 337-1, VDE 0660
-5~+65(with no icing)
-5~+65(with no icing)
95RH Max.
Mechanical durable: 1000m/s2 min.
Malfunction: 300m/s2 min.
Malfunction: 10 to 55HZ, 1.5mm double amplitude
6-8 kgf-cm
Cover 12-14 kgf-cm/Head 8-9 kgf-cm/Mounting 50-60 kgf/cm
Φ2Max
Φ12 Max(IP 65 if use cableΦ8-9)
Greegoo Electric 7.2007

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]