Limit Switchs
CHL Limit switch
Features
------------------------------------------------------------------------------------------------------------
Metallic bottom shell
Stainless steel roller, punch and spring
Strong electric property 10A, 250V, for 500,000 times
Electrical life
Specifications
Model
Operating force
Release force
Pre-travel
Tripping position
Movement differential
Over travel
Total travel
CHL
OF Max
RF Min
PT Max
TP ± 10%
MD Max
OT Min
TT Min
Characteristics
Double Break Mechanism
Rated Voltage / Current
Contact Resistance
Insultation Resistance
Dielectric Strength
Electrical Life
Mechanical Life
Operating Speed
Degree of Protection
Ambient Temperature Rised
Conformed Standards
Operating Temperature
Storage Temperature
Ambient Operating Humdity
Shock Resistance
Vibration Frequency
Terminal Screw Torsional Force
Other Screw Torsional Force
Bare Wire Diameter
Cable Diameter
5000
750g-cm
100g-cm
20°
22.5°
10°
75°
95°
5030
750g-cm
100g-cm
20°
22.5°
10°
75°
95°
5050
750g-cm
100g-cm
20°
22.5°
10°
75°
95°
5100
750g-cm
200g
1.8mm
2.0mm
1.2mm
4.0mm
5.8mm
5200
900g-cm
200g
1.8mm
2.0mm
1.2mm
4.0mm
5.8mm
5220
900g-cm
200g
1.8mm
2.0mm°
1.2mm
4.0mm
5.8mm
5300
150g
30g
30mm
22.5°
14°
20mm
50mm
5330
150g
30g
30mm
22.5°
14°
20mm
50mm
5381
150g
30g
30mm
22.5°
14°
20mm
50mm
5391
550g-cm
100g-cm
20°
22.5°
14°
75°
95°
INO+INC Force Break snap action
10(4)A, 125, 250VAC / 6(2)A, 380VAC For inductance Load, CosΦ=0.4
25mΩmax. (initial value)
100mΩmin. (at 500VDC)
1000VAC, 50/60 HZ for 1 minute between terminals of the same polarity
1500VAC, 50/60 HZ for 1 minute between current-carrying and non-current-carrying metal parts
1500VAC, 50/60 HZ for 1 minute between each terminal and ground
500,000 at 10A 250VAC Resistive
10, 000, 000 operations min. (under rated conditions)
5mm/s to 0.5m/s
IP65
Max 30over ambient temperature at rated voltage/current
Cenelec EN 50041, EN 50047, IEC 337-1, VDE 0660
-5~+65(with no icing)
-5~+65(with no icing)
95RH Max.
Mechanical durable: 1000m/s2 min.
Malfunction: 300m/s2 min.
Malfunction: 10 to 55HZ, 1.5mm double amplitude
6-8 kgf-cm
Cover 12-14 kgf-cm/Head 8-9 kgf-cm/Mounting 50-60 kgf/cm