OPB780-Kit
Color Sensor Evaluation Kit
Below are the operating characteristics of the
OPB780Z. As the ambient temperature or other
environmental conditions change, the values noted
may vary. The OPB780Z is designed to operate
between –40°C and +85°C. The OPB780Z provides
consistent recognition of a color given constant
environmental conditions.
Operating Characteristics at VDD = 5 V, TA = 25°C
Clear Diode Blue Diode Green Diode Red Diode
Parameter Test Conditions S2 = H, S3 = L S2 = L, S3 = H S2 = H, S3 = H S2 = L, S3 = L Units
Output
Frequency
(fO)
Ee = 47.2 µW/cm2
λP = 470 nm
Ee = 40.4 µW/cm2
λP = 524 nm
Ee = 34.6 µW/cm2
λP = 640
Dark Frequency Ee = 0
Min Typ Max Min Typ Max Min Typ Max Min Typ Max
16.0 20.0 24.0 11.2 16.4 21.6 -
-
-
-
-
-
kHz
16.0 20.0 24.0 -
-
- 8.0 13.6 19.2 -
-
-
kHz
16.0 20.0 24.0 -
-
-
-
-
- 14.0 19.0 24.0
kHz
-
2 12 -
2 12 -
2 12 -
2 12
Hz
Irradiance
Responsivity
(Re)
(See Note 1)
λP = 470 nm
λP = 524 nm
λP = 565 nm
λP = 640 nm
- 424 -
- 495 -
- 532 -
- 578 -
- 348 -
- 163 -
- 37 -
- 17 -
- 81 -
- 337 -
- 309 -
- 29 -
- 26 -
- 35 -
- 91 -
- 550 -
Hz /
( µW/cm2)
λP = 470 nm
- 1410 -
- 1720 -
-
-
-
-
-
-
Saturation
Irradiance
(See Note 2)
λP = 524 nm
λP = 565 nm
- 1210 -
-
-
-
- 1780 -
-
-
-
( µW/cm2)
- 1130 -
-
-
-
- 1940 -
-
-
-
λP = 640 nm
- 1040 -
-
-
-
-
-
-
- 1090 -
Illuminance
Responsivity
(RV)
(See Note 3)
λP = 470 nm
λP = 524 nm
λP = 565 nm
λP = 640 nm
- 565 -
- 95 -
- 89 -
- 373 -
- 464 -
- 31 -
-
6
-
- 11 -
- 108 -
- 65 -
- 52 -
- 19 -
- 35 -
-
7
-
- 15 -
- 355 -
Hz / Lux
Nonlinearity
(See Note 4)
(fO) = 0 to 5 kHz
(fO) = 0 to 50 kHz
(fO) = 0 to 500 kHz
- ±0.1 -
- ±0.2 -
- ±0.5 -
- ±0.1 -
- ±0.2 -
- ±0.5 -
- ±0.1 -
- ±0.2 -
- ±0.5 -
- ±0.1 -
- ±0.2 -
- ±0.5 -
%
Full
Scale
Notes:
1. Irradiance Responsivity (Re) is measured over the range from Frequency 0 to 5 kHz.
2. Saturation Irradiance—(Full-Scale Frequency) / (Irradiance Responsivity)
3. Illuminance Responsivity is calculated from the Irradiance Responsivity using the appropriate wavelength
LED.
4. Nonlinearity is defined as the deviation of the Output Frequency utilizing a straight line between 0 and full
scale and is expressed as a percent of full scale.
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Issue A.2 11/09
Page 3 of 9