74AHC1G02; 74AHCT1G02
2-input NOR gate
Table 7. Static characteristics …continued
Voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions
ICC
ICC
CI
supply current VI = VCC or GND; IO = 0 A;
VCC = 5.5 V
additional
per input pin; VI = 3.4 V;
supply current other inputs at VCC or GND;
IO = 0 A; VCC = 5.5 V
input
capacitance
25 C
40 C to +85 C 40 C to +125 C Unit
Min Typ Max Min
Max
Min
Max
-
- 1.0
-
10
-
40 A
-
- 1.35 -
1.5
-
1.5 mA
- 1.5 10
-
10
-
10 pF
11. Dynamic characteristics
Table 8. Dynamic characteristics
GND = 0 V; tr = tf = 3.0 ns. For test circuit see Figure 6.
Symbol Parameter Conditions
25 C
40 C to +85 C 40 C to +125 C Unit
Min Typ Max Min Max
Min
Max
For type 74AHC1G02
tpd
propagation A and B to Y; see Figure 5 [1]
delay
VCC = 3.0 V to 3.6 V
[2]
CL = 15 pF
- 4.4 7.9 1.0
9.5
1.0
10.5 ns
CL = 50 pF
- 6.3 11.4 1.0
13
1.0
14.5 ns
VCC = 4.5 V to 5.5 V
[3]
CL = 15 pF
- 3.2 5.5 1.0
6.5
1.0
7.0 ns
CL = 50 pF
- 4.6 7.5 1.0
8.5
1.0
9.5 ns
CPD
power
per buffer;
[4] -
18
-
-
-
-
-
pF
dissipation CL = 50 pF; f = 1 MHz;
capacitance VI = GND to VCC
For type 74AHCT1G02
tpd
propagation A and B to Y; see Figure 5 [1]
delay
VCC = 4.5 V to 5.5 V
[3]
CL = 15 pF
- 3.5 5.5 1.0
6.5
1.0
7.0 ns
CL = 50 pF
- 4.9 7.5 1.0
8.5
1.0
9.5 ns
CPD
power
per buffer;
[4] -
19
-
-
-
-
-
pF
dissipation CL = 50 pF; f = 1 MHz;
capacitance VI = GND to VCC
[1] tpd is the same as tPLH and tPHL.
[2] Typical values are measured at VCC = 3.3 V.
[3] Typical values are measured at VCC = 5.0 V.
[4] CPD is used to determine the dynamic power dissipation PD (W).
PD = CPD VCC2 fi + (CL VCC2 fo) where:
fi = input frequency in MHz; fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in Volts.
74AHC_AHCT1G02
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 7 — 6 November 2014
© Nexperia B.V. 2017. All rights reserved
5 of 12

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]