datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

GA100-005WD Просмотр технического описания (PDF) - Unspecified

Номер в каталоге
Компоненты Описание
Список матч
GA100-005WD Datasheet PDF : 3 Pages
1 2 3
Ares Series
PCB Mounted
Pressure Transducer
Common Specifications (all specifications are at 77°F [25°C] unless otherwise noted)
Supply Voltage .............................................................................................................................................................................5V
Maximum Proof Pressure to any Port ................................................................................................................................... 5 psi
Burst Pressure ...................................................................................................................................................... 10 psig all ranges
Maximum Common Mode Pressure ................................................................................................................... 10 psi all ranges
Media ........................................................................................................... Non-Ionic, Non-Corrosive media (clean, dry gases)
Humidity ........................................................................................................................................................95% non-condensing
Shock ............................................................................. 50 g, 11 msec, 1/2 sine per Mil Std 202F, Method 213B, Condition A
Vibration .............................................................................................................. 10 g sinusoidal peak to peak per Mil Std 810C
Long Term Drift .................................................................................................................................................... ±0.5%FSO/year
Reflow Temperature .......................................................................................................................................... 240°C (5 sec max)
Temperature Range
Compensated ............................................................................................................................................................. 0° to 60°C
Operating ................................................................................................................................................................ -25° to 80°C
Storage ..................................................................................................................................................................... -25° to 80°C
Specifications by Model
Offset1 (V)
GA100 Series GA200 Series
0.5 ±0.050 0.25 ±0.050
Span1,3 (V)
4.0 ±0.025 3.75 ±0.025
Input Voltage3 (V)
5.0 ±0.25
Output Impedance (Max)
5
Temperature Error
(Over the Compensated Range)
Span Error (%FSO)
Zero Error (%FSO)
1.5%
1.5%
1 At 5.00 VDC input voltage.
2 Output is ratiometric to input voltage variation.
3 The span is defined as the algebraic difference between
the electrical output at full scale pressure voltage and the
electrical output at zero pressure.
Standard Pressure Ranges
Ares
Model Number
GA100-005WD
GA100-010WD
GA100-015WD
GA100-001PD
GA200-005WD
GA200-010WD
GA200-015WD
GA200-001PD
Operating
Pressure
0 to 5” H2O
0 to 10” H2O
0 to 15” H2O
0 to 1 PSI
0 to 5” H2O
0 to 10” H2O
0 to 15” H2O
0 to 1 PSI
Accuracy
%FSO4
0.25%
0.5%
0.5%
0.75%
0.25%
0.5%
0.5%
0.75%
4 Includes effects of non-linearity, hysteresis and
repeatability
Output Connection Diagram
Power Supply
1
Ground
2
V (OUT)
3
5 VDC Only
Power Supply
Output
V Voltage
Meter
209

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]