M54/M74HCT374/534
AC ELECTRICAL CHARACTERISTICS (CL = 50 pF, Input tr = tf = 6 ns)
Symbol
Parameter
Test Conditions
VCC CL
(V) (pF)
tTLH Output Transition 4.5 50
tTHL Time
tPLH Propagation
4.5 50
tPHL Delay Time
4.5 150
(CLOCK - Q, Q)
TA = 25 oC
54HC and 74HC
Value
-40 to 85 oC -55 to 125 oC Unit
74HC
54HC
Min. Typ. Max. Min. Max. Min. Max.
7 12
15
18
ns
20 30
38
45
ns
25 38
48
57
ns
tPZL Output Enable
4.5 50 RL = 1 K
17 30
38
45
ns
tPZH Time
4.5 150 RL = 1 K
25 38
48
57
ns
tPZL Output Disable
tPZH Time
4.5 50 RL = 1 K
16 28
35
42
ns
fMAX Maximum CLock 4.5 50
Frequency
31 50
25
21
ns
tW(L)
tW(H)
Minimum Pulse
Width (CLOCK)
4.5 50
15
19
23
ns
ts
Minimum Set-up 4.5 50
Time
15
19
23
ns
th
Minimum Hold
Time
4.5 50
0
0
0
ns
CIN Input Capacitance
5 10
10
10
pF
COUT Out put
10
Capacitance
pF
CPD (*) Power Dissipation
48
Capacitance
pF
(*) CPD is defined as the value of the IC’s internal equivalent capacitance which is calculated from the operating current consumption without load.