datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

HX2-1.5V Просмотр технического описания (PDF) - Matsushita Electric Works

Номер в каталоге
Компоненты Описание
Список матч
HX2-1.5V Datasheet PDF : 3 Pages
1 2 3
HX-RELAYS Compact & Slim 2 Form C
Non-polarized Relay
7.4
15.0
.291
.591
9.4
.370
mm inch
FEATURES
• Compact size of (W) 7.4 × (L) 15.0 × (H)
9.4 mm (W) .291× (L) .591× (H) .370
inch.
• Surge withstand voltage of 1,500 V
(between contact and coil)
Conforms to FCC Part 68.
• High-density mounting is possible
• High reliability
The use of a gold-clad bifurcated struc-
ture for the movable contacts, and a low
gas material for the forming materials and
coil wiring ensures high contact reliability.
SPECIFICATIONS
Contact
Arrangement
2 Form C
Initial contact resistance
(By voltage drop 6 V DC 1 A)
Max. 100 m
Contact material
Gold-clad silver alloy
Nominal switching
capacity (resistive load)
1 A 30 V DC, 0.3 A 125 V AC
Rating
Max. switching power
(resistive load)
Max. switching voltage
30 W (DC), 37.5 VA (AC)
110 V DC, 125 V AC
Max. switching current
Min. switching capability f1
1A
1 mA 1 V DC
Nominal operating power
320 mW
Mechanical (at 180 cpm)
Expected
life (min.
operations) Electrical (at 20 cpm)
10 7
105
(1 A 30 V DC,
0.3 A 125 V AC resistive)
Note:
f1This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the ac-
tual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section.
*2 By resistive method, nominal voltage applied to the coil; contact carrying current:
1A.
*3 Nominal voltage applied to the coil, excluding contact bounce time.
*4 Half- wave pulse of sine wave: 11ms, detection time: 10µs
*5 Half- wave pulse of sine wave: 6ms
*6 Detection time: 10µs
*7 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61)
Characteristics
Initial insulation*1 resistance
Initial
breakdown
voltage
Between contacts
Between contact and
coil
Between contacts sets
Temperature rise*2
Operate time*3
(at 20°C 68°F)
Release time(without diode)*3
(at 20°C 68°F)
Shock resistance
Functional* 4
Destructive*5
Vibration resistance
Functional* 6
Destructive
Conditions for
opetation, transport
and storage*7
Unit weight
Ambient
temperature
Humidity
Atmospheric
pressure
Min. 1,000 M(at 500 V DC)
750 V rms for 1 min.
1,000 V rms for 1 min.
1,000 V rms for 1 min.
Max. 60°C
Max. 6 ms (Approx. 4 ms)
Max. 5 ms (Approx. 3 ms)
Min. 100 m/s2 {10G}
Min. 1,000 m/s2 {100G}
10 to 55 Hz
at double amplitude of 1.0 mm
10 to 55 Hz
at double amplitude of 1.5 mm
–40 to +70°C
–40 to +158°F
5 to 85% R.H.
86 to 106 kPa
Approx. 2g .07 oz
TYPICAL
APPLICATIONS
• Telephone exchange, transmission
equipment
• Communications devices
• Measurement devices
• Home appliances, and audio/visual
equipment
• Office equipment
ORDERING INFORMATION
Ex. HX 2
3V
Contact arrangement
2: 2 Form C
Note: 2,500V Surge (Bellcore) type is also available.
Please consult us for details.
Coil voltage(DC)
1.5, 3, 4.5, 5, 6, 9, 12, 24 V
183