12-Bit A/D Converter
7672
PARAMETER
TABLE 4. 7672 DC ELECTRICAL CHARACTERISTICS
(VDD = 5V ±5%, VSS = -12V ±10%, VREF = -5V, TA = -55 TO 125 °C UNLESS OTHERWISE SPECIFIED)
SYMBOL TEST CONDITION
SUBGROUPS MIN
MAX
Bipolar Zero Error
Bipolar Gain Error
1. Guaranteed by design.
BZE TA = +25°C
TA = -55 to +125°C
BGE TA = +25°C
TA = -55 to +125°C
1
--
±5
2, 3
--
±6
1
--
±5
2, 3
--
±7
UNITS
LSB
LSB
PARAMETER
TABLE 5. 7672 TIMING CHARACTERISTICS 1,2
(VDD = 5V ±5%, VSS = -12V ±10%, VREF = -5V, TA = -55 TO 125 °C UNLESS OTHERWISE SPECIFIED)
TEST CONDITION
SUBGROUPS SYMBOL MIN MAX
UNITS
Conversion Time, Synchronous Clk, 3 12.5 clks, TA = -55 to +125 °C
9, 10, 11 tCONV -- 5.0 us
Conversion Time, Asynchronous Clk, 12-13 clks, TA = -55 to +125 °C
9, 10, 11 tCONV 4.8 5.2 us
CS to RD Setup Time
TA = -55 to +125 °C
9, 10, 11 t1
0
-- ns
RD to BUSY Delay
CL = 50 pF, TA = +25 °C
9
t2
-- 190 ns
CL = 50 pF, TA = -55 to +125 °C
10, 11
-- 270
Data Access Time 4
CL = 100 pF, TA = +25 °C
9
t3
-- 125 ns
CL = 100 pF, TA = -55 to +125 °C 10, 11
-- 170
RD Pulse Width
TA = -55 to +125 °C
9, 10, 11 t4
t3 -- ns
CS to RD Hold Time
TA = -55 to +125 °C
9, 10, 11 t5
0
-- ns
Data Setup Time After BUSY4
CL = 100 pF, TA = +25 °C
9
t6
-- 70 ns
CL = 100 pF, TA = -55 to +125 °C 10, 11
--
-- 100
Bus Relinguish Time5
(TA = +25 °C)
(-55 < TA < +125 °C)
9
t7
-- 75 ns
10, 11
-- 90
Delay Between Read Operations
(-55 < TA < +125 °C)
9, 10, 11 t8
200 -- ns
1. 1LSB = FS/4096; TA = 25 °C; Performance over power supply tolerance is guaranteed by power supply rejection test.
2. All inputs are 0V to +5V swing with tr = tr = 5ns (10 to 90% of +5V) and timed from a voltage level of +1.6V.
3. Functionally tested.
4. t3 and t6 are measured with the load circuits of Figure 1 and are defined as the time required for an output to cross +0.8 or
+2.4.
5. t7 is defined as the time required for the data lines to change 0.5V when loaded with the circuit of Figure 2.
08.09.02 REV 13