MIC5233
Absolute Maximum Ratings (Note 1)
Input Supply Voltage ....................................... 20V to 38V
Enable Input Voltage ...................................... 0.3V to 38V
Power Dissipation .................................... Internally Limited
Junction Temperature .............................. 40°C to +125°C
Storage Temperature ............................... 65°C to +150°C
ESD Rating, Note 3
Micrel
Operating Ratings (Note 2)
Input Supply Voltage ........................................ 2.3V to 36V
Enable Input Voltage ........................................... 0V to 36V
Junction Temperature (TJ) ....................... 40°C to +125°C
Package Thermal Resistance
SOT-23-5 JA) .................................................. 235°C/W
Electrical Characteristics (Note 4)
TA = 25°C with VIN = VOUT + 1V; IOUT = 100µA; VEN 2V; Bold values indicate 40°C < TJ < +125°C; unless otherwise specified.
Parameter
Condition
Min Typ Max Units
Output Voltage Accuracy
Variation from nominal VOUT
1.0
+1.0
%
2.0
+2.0
%
Line Regulation
Load Regulation
Dropout Voltage
VIN = VOUT + 1V to 36V
IOUT = 100µA to 100mA
IOUT = 100µA
IOUT = 50mA
IOUT = 100mA
0.04 0.5
%
0.25
1
%
50
mV
230 300 mV
400 mV
270 400 mV
450 mV
Ground Current
Ground Current in Shutdown
Short Circuit Current
Output Leakage,
Reverse Polarity Input
IOUT = 100µA
IOUT = 50mA
IOUT = 100mA
VEN 0.6V; VIN = 36V
VOUT = 0V
Load = 500; VIN = 15V
18
30
µA
35
µA
0.35 0.70 mA
1
2
mA
0.1
1
µA
190 350 mA
0.1
µA
Enable Input
Input Low Voltage
Regulator OFF
0.6
V
Input High Voltage
Regulator ON
2.0
V
Enable Input Current
VEN = 0.6V; Regulator OFF
VEN = 2.0V; Regulator ON
VEN = 36V; Regulator ON
1.0 0.01 1.0
µA
0.1
1.0
µA
0.5
2.5
µA
Note 1.
Note 2.
Note 3.
Note 4.
Exceeding the absolute maximum rating may damage the device.
The device is not guaranteed to function outside its operating rating.
Devices are ESD sensitive. Handling precautions recommended. Human body model, 1.5k in series with 100pF.
Specification for packaged product only.
August 2003