datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

C67078-S5204-A4(2003) Просмотр технического описания (PDF) - Infineon Technologies

Номер в каталоге
Компоненты Описание
Список матч
C67078-S5204-A4
(Rev.:2003)
Infineon
Infineon Technologies Infineon
C67078-S5204-A4 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
BTS 307
Truth Table
Input- Output Status
Normal
operation
Open load
Short circuit
to GND
Short circuit
to Vbb
Overtem-
perature
Under-
voltage
Overvoltage
level
level
BTS 307
BTS 707
L
L
L
H
H
H
L
9)
H
H
H
H
L
L
L
H
L
L
L
H
H
H
H
H
L
L
L
H
L
L
L
L
L
H
L
L
no overvoltage shutdown,
see normal operation
L = "Low" Level
H = "High" Level
X = don't care
Z = high impedance, potential depends on external circuit
Status signal after the time delay shown in the diagrams (see fig 5. page 10)
Terms
Status output
Ibb
3
I IN
IN
Vbb
2
IL
I ST
PROFET
OUT
5
ST
4
V IN VST
GND
Vbb
1 IGND
R GND
VON
VOUT
R ST(ON)
+5V
ST
GND
ESD-
ZD
ESD-Zener diode: 6.1 V typ., max 5 mA;
RST(ON) < 0 at 1.6 mA, ESD zener diodes are not to
be used as voltage clamp at DC conditions. Operation
in this mode may result in a drift of the zener voltage
(increase of up to 1 V).
Input circuit (ESD protection)
IN
RI
Short circuit detection
Fault Signal at ST-Pin: VON > 2.5 V typ, no switch off by
the PROFET itself, external switch off recommended!
+ Vbb
ESD-ZD I
II
V
ON
GND
OUT
ESD zener diodes are not to be used as voltage clamp
at DC conditions. Operation in this mode may result in
Logic
unit
Short circuit
detection
a drift of the zener voltage (increase of up to 1 V).
9) Power Transistor off, high impedance, internal pull up current source for open load detection.
Semiconductor Group
5
2003-Oct-01