datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

NUP2105L Просмотр технического описания (PDF) - ON Semiconductor

Номер в каталоге
Компоненты Описание
Список матч
NUP2105L Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
NUP2105L, SZNUP2105L
APPLICATIONS
Background
The Controller Area Network (CAN) is a serial
communication protocol designed for providing reliable
high speed data transmission in harsh environments. TVS
diodes provide a low cost solution to conducted and radiated
Electromagnetic Interference (EMI) and Electrostatic
Discharge (ESD) noise problems. The noise immunity level
and reliability of CAN transceivers can be easily increased
by adding external TVS diodes to prevent transient voltage
failures.
The NUP2105L provides a transient voltage suppression
solution for CAN data communication lines. The
NUP2105L is a dual bidirectional TVS device in a compact
SOT−23 package. This device is based on Zener technology
that optimizes the active area of a PN junction to provide
robust protection against transient EMI surge voltage and
ESD. The NUP2105L has been tested to EMI and ESD
levels that exceed the specifications of popular high speed
CAN networks.
CAN Physical Layer Requirements
Table 1 provides a summary of the system requirements
for a CAN transceiver. The ISO 11898−2 physical layer
specification forms the baseline for most CAN systems. The
transceiver requirements for the Honeywell® Smart
Distribution Systems (SDS®) and Rockwell
(Allen−Bradley) DeviceNethigh speed CAN networks
are similar to ISO 11898−2. The SDS and DeviceNet
transceiver requirements are similar to ISO 11898−2;
however, they include minor modifications required in an
industrial environment.
Table 1. Transceiver Requirements for High−Speed CAN Networks
Parameter
ISO 11898−2
SDS Physical Layer
Specification 2.0
Min / Max Bus Voltage
(12 V System)
−3.0 V / 16 V
11 V / 25 V
Common Mode Bus Voltage
CAN_L:
−2.0 V (min)
2.5 V (nom)
CAN_H:
2.5 V (nom)
7.0 V (max)
Same as ISO 11898−2
Transmission Speed
1.0 Mb/s @ 40 m
125 kb/s @ 500 m
Same as ISO 11898−2
ESD
Not specified, recommended
w $8.0 kV (contact)
Not specified, recommended
w $8.0 kV (contact)
EMI Immunity
ISO 7637−3, pulses ‘a’ and ‘b’ IEC 61000−4−4 EFT
Popular Applications
Automotive, Truck, Medical
and Marine Systems
Industrial Control Systems
DeviceNet
Same as ISO 11898−2
Same as ISO 11898−2
500 kb/s @ 100 m
125 kb/s @ 500 m
Not specified, recommended
w $8.0 kV (contact)
Same as ISO 11898−2
Industrial Control Systems
www.onsemi.com
4

Share Link: 