MAX1795/MAX1796/
MAX1797
Low-Supply Current, Step-Up DC-DC Converters
with True Shutdown
Electrical Characteristics (continued)
(VBATT = +2V, OUT = FB (VOUT = +3.3V), SHDN = LBI = GND, TA = 0°C to +85°C, unless otherwise noted. Typical values are at
TA = +25°C.)
PARAMETER
Operating Current into BATT
Shutdown Current into BATT
LX Switch MaxImum On-Time
LX Switch Minimum Off-Time
LBI Threshold Voltage Falling
LBI Hysteresis
LBI Input Current
LBO Low Output Voltage
LBO Off-Leakage Current
SHDN Input Voltage
Shutdown Input Current
SYMBOL
tON
tOFF
VLBI
CONDITIONS
VFB = +1.4V, VLBI = +1V
SHDN = BATT, VLBI = +1V
VFB = +1V, if current limit not reached
VFB = +1V
VBATT = +2V
VBATT = LBI
ILBI
VLBI = +0.8V
VBATT = VLBI = +0.975V,
sinking 20µA (50Ω typ)
VBATT = VLBI = +1.1V,
sinking 100µA (25Ω typ)
VLBO = +5.5V
VIL
VIH
VSHDN = 0 and +5.5V
MIN
3
0.8
0.8
0.875
TYP
2
2
4
1
0.85
0.925
25
9
MAX
4
4
5
1.2
0.90
0.975
100
UNITS
µA
µA
µs
µs
V
mV
nA
0.1
V
0.1
1
100
nA
0.8 x
VBATT
0.2 x
VBATT
V
100
nA
Electrical Characteristics
(VBATT = +2V, OUT = FB (VOUT = +3.3V), SHDN = LBI = GND, TA = -40°C to +85°C, unless otherwise noted.) (Note 3)
PARAMETER
Operating Voltage
Output Voltage
SYMBOL
VBATT
VOUT
Note 1
FB = OUT
FB = GND
CONDITIONS
MIN
MAX
1.0
5.5
3.13
3.47
4.75
5.25
Adjustable Output Voltage Range
2.0
5.5
Steady-State Output Current
(Note 1)
IOUT
FB = OUT
(VOUT = +3.3V)
FB = GND
(VOUT = +5.0V)
MAX1795
100
MAX1796
200
MAX1797
400
MAX1795
60
MAX1796
125
MAX1797
250
Feedback Set-Point Voltage
(Adjustable Mode)
VFB
VOUT = +2V to +5.5V
1.19
1.29
Feedback Input Current
IFB
VFB = +1.25V
100
UNITS
V
V
V
mA
V
nA
www.maximintegrated.com