datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

V58C3643204SATL-60 Просмотр технического описания (PDF) - Mosel Vitelic, Corp

Номер в каталоге
Компоненты Описание
Список матч
V58C3643204SATL-60
MOSEL
Mosel Vitelic, Corp MOSEL
V58C3643204SATL-60 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MOSEL VITELIC
V58C3643204SAT
DC Characteristics
Recommended operating conditions Unless Otherwise Noted, TA=0 to 70°C
Version
Parameter
Symbol
Test Condition
-45 -50 -55 -60 Unit Note
Operating Current
(One Bank Active)
Precharge Standby Current in
Power-down mode
ICC1
Burst Lenth = 2 tRC Š tRC(min)
350 340 330 330 mA
1
IOL= 0mA, tCC = tCC(min)
ICC2P CKE ð VIL(max), tCC = tCC(min)
60
mA
Precharge Standby Current in Non
Power-down mode
ICC2N
CKE ð VIH(min), CS Š VIH(min),
tCC = tCC(min)
165 160 155 150 mA
Active Standby Current power-down mode ICC3P CKE ð VIL(max), tCC = tCC(min)
95
mA
Active Standby Current in in Non
Power-down mode
ICC3N
CKE Š VIH(min), CS Š VIH(min),
tCC = tCC(min)
205 200 195 190 mA
Operating Current
(Burst Mode)
ICC4
IOL = 0mA, tCC = tCC(min),
470 450 430 410 mA 1
Page Burst, All Banks activated
Refresh Current
Self Refresh Current
ICC5
ICC6
tRC Š tRFC(min)
CKE ð 0.2V
470 450 430 410 mA 2
4
mA
Notes: 1. Measured with outputs open.
2. Refresh period is 16ms.
Absolute Maximum Ratings
Parameter
Voltage on any pin relative to VSS
Voltage on VDD supply relative to VSS
Storage temperature
Power dissipation
Short circuit current
Symbol
VIN, VOUT
VDD, VDDQ
TSTG
PD
IOS
Value
-1.0 ~ 4.6
-1.0 ~ 4.6
-55 ~ +150
1.6
50
Note: Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS are exceeded.
Functional operation should be restricted to recommended operating condition.
Exposure to higher than recommended voltage for extended periods of time could affect device reliability.
Unit
V
V
°C
W
mA
V58C3643204SAT Rev. 1.4 August 2001
6

Share Link: 