MB86615
2.6.3 Receiving Operation
(1) Start Receiving Operation
Parameter
ICLK rise to ILWRE fall
IV setup time
Data output definition time
Data output disable time
IV fall to ICRCE fall time*
Symbol
tWREH
tSIV
tDZ
tD
tERRL
Min.
—
40
—
10
—
Value
* : The ICRCE signal is output when a CRC error is detected in receiving data.
Max.
40
—
40
40
40
Unit
ns
ns
ns
ns
ns
ICLK
IDIR
tWREH
ILWRE
tSIV
IV
tDZ
tD
ID7 to ID0
Hi − Z
1
2
3
tERRL
ICRCE
37