RS5C372A/B
2.3 Clock Counter (at internal address 0-2h)
· Time digit display (in BCD code)
Second digits : Range from 00 to 59 and carried to minute digits when incremented from 59 to 00.
Minute digits : Range from 00 to 59 and carried to hour digits when incremented from 59 to 00.
Hour digits : See descriptions on the 12/24 bit (Section 2.2-1).
Carried to day and day-of-the-week digits when incremented from 11 p.m. to 12 a.m. or 23 to 00.
· Any registered imaginary time should be replaced with correct time as carrying to such registered imaginary time
digits from lower-order ones cause the clock counter malfunction.
2.3-1 Second digit register (at internal address 0h)
D7
D6
D5
D4
D3
D2
D1
D0
—
S40
S20
S10
S8
S4
S2
S1
(For write operation)
0
S40
S20
S10
S8
S4
S2
S1
(For read operation)
0
Undefined Undefined Undefined Undefined Undefined Undefined Undefined Default*
2.3-2 Minute digit register (at internal address 1h)
D7
D6
D5
D4
D3
D2
D1
D0
—
M40
M20
M10
M8
M4
M2
M1
(For write operation)
0
M40
M20
M10
M8
M4
M2
M1
(For read operation)
0
Undefined Undefined Undefined Undefined Undefined Undefined Undefined Default*
2.3-3 Hour digit register (at internal address 2h)
D7
D6
D5
D4
D3
D2
D1
D0
—
—
P/A or H20 H10
H8
H4
H2
H1
(For write operation)
0
0
P/A or H20 H10
H8
H4
H2
H1
(For read operation)
0
0
Undefined Undefined Undefined Undefined Undefined Undefined Default*
*) The default means read value when XSTP bit is set to “1” by starting up from 0V, or supply voltage drop, etc.
21