IGBT Modules
7MBR15SA120
[ Inverter ]
Switching time vs. Collector current (typ.)
Vcc=600V, VGE=±15V, Rg=82Ω, Tj=25°C
1000
toff
500
ton
tr
100
tf
50
0
5
10
15
20
25
Collector current : Ic [ A ]
[ Inverter ]
Switching time vs. Gate resistance (typ.)
Vcc=600V, Ic=15A, VGE=±15V, Tj=25°C
5000
1000
500
toff
ton
tr
100
tf
50
30
100
Gate resistance : Rg [ Ω ]
[ Inverter ]
Switching loss vs. Gate resistance (typ.)
Vcc=600V, Ic=15A, VGE=±15V, Tj=125°C
12
1000
10
Eon
8
6
4
Eoff
2
Err
0
30
100
1000
Gate resistance : Rg [ Ω ]
1000
500
[ Inverter ]
Switching time vs. Collector current (typ.)
Vcc=600V, VGE=±15V, Rg=82Ω, Tj=125°C
toff
ton
tr
tf
100
50
0
5
10
15
20
25
Collector current : Ic [ A ]
[ Inverter ]
Switching loss vs. Collector current (typ.)
Vcc=600V, VGE=±15V, Rg=82Ω
5
4
Eon(125 oC)
3
Eon(25 oC)
2
Eoff(125 oC)
Eoff(25 oC)
1
Err(125 oC)
Err(25 oC)
0
0
5
10
15
20
25
30
Collector current : Ic [ A ]
[ Inverter ]
Reverse bias safe operating area
+VGE=15V, -VGE=<15V, Rg=>82Ω, Tj=<125°C
40
30
20
10
0
0
200
400
600
800
1000
1200
1400