+48V Quad Hot-Swap Controllers For
Power-Over-LAN
Typical Operating Characteristics (continued)
(VCSP_ = VCC = +48V, VDD = +3.3V, VRLY = +12V, VAGND = VDGND = 0V, RTIM = open, TA = +25°C, unless otherwise specified.)
tO vs. INPUT VOLTAGE
125
RETRY DUTY CYCLE vs. DC
MAX5913A/14A toc35
CHANNEL-TO-CHANNEL CROSSTALK
MAX5913A/14A toc36
100
RRTIM = 40k
75
50
25 RRTIM = OPEN
RRTIM = 2k
0
1.8 2.1 2.4 2.7 3.0 3.3 3.6
VDD (V)
A
VTEST
0
5V/div
B
0
VOUT
C
10mV/div
0
100ms/div
VGATE = 20V/div, RRTIM = 2k
A: VGATE, 20V/div, DC = UNCONNECTED (4%)
B: VGATE, 20V/div, DC = VDD (2%)
C: VGATE, 20V/div, DC = GND (1%)
20µs/div
SEE FIGURE 4 FOR TEST CIRCUIT
Pin Description
PIN
1
2, 3, 4, 5
NAME
FAULT
STAT1,
STAT2,
STAT3,
STAT4
FUNCTION
Active-Low Fault Output. FAULT is an open-drain output that goes low when a fault is
detected on any of the four channels. FAULT is low when an OC (open circuit) is
detected, or when the MAX5913A/MAX5914A is in auto-retry caused by an overcurrent
condition. When RTRYEN is low, and the channel switch is latched off due to an
overcurrent condition, FAULT remains low until ON_ is driven low.
Status Outputs. STAT_ are push-pull outputs. Depending on the STATOUT pin status,
STAT_ flags either the Power-OK_ or Port-OC_ status.
Power-OK_ high indicates:
a) ON_ input is high.
b) The switch port is fully on and startup is completed (VCSP_ - VOUT_) < VSWON.
c) Input voltage is above VUVLO.
d) Switch is not in current limit.
Power-OK_ low indicates a fault with any of the above conditions. Port-OC_ output high
indicates that the switch is latched off because the switch current is less than the open-
current threshold, Port-OC is low otherwise.
6, 10, 24, 28
CSP4, CSP3, CSP2,
CSP1
Current-Sense Positive Input. Connect to VCC and place a current-sense resistor from CSP_
to DRAIN_. Use a Kelvin sense trace from a current-sense resistor to CSP_ (see Figure 7).
7, 11, 23, 27
DRAIN4, DRAIN3,
DRAIN2, DRAIN1
MOSFET Drain Current-Sense Negative Input. Connect to drain of power MOSFET and
connect a current-sense resistor from CSP_ to DRAIN_. Use Kelvin sense trace from
current-sense resistor to DRAIN_ (see Figure 7).