M52723ASP
GHP1 H Para. Gain Control1
Measure the amplitude of parabola waveform at pin 7 and it is defined as HP6 1.0 V.
GHP2 H Para. Gain Control2
The amplitude of parabola waveform at pin 7 is defined as HP6 2.5 V.
GHP2 =
HP6 2.5 V HP6 1.0 V
1.5
GHP3 H Para. Gain Control3
Measure the amplitude of parabola waveform at pin 7. (Limit level)
DLI H Para. Limit Size Temperature Drift
Measure temperature drift of GHP3. (20°C to 85°C)
I6 Pin 6 Input Current
Measure the input current to pin 6 when voltage of pin 6 is 2.5 V.
I19 Pin 19 Input Current
Measure the input current to pin 19 when voltage of pin 19 is 2 V.
AVP1 V Parabola Accuracy1
Measure the output voltage at pin 4 and it is defined as VP2 3.5 V.
AVP2 V Parabola Accuracy2
The output voltage at pin 4 is defined as VP2 1.9 V.
AVP2 = VP2 3.5 V VP2 1.9 V
AVP3 V Parabola Accuracy3
The output voltage at pin 4 is defined as VP2 2.7 V.
AVP3 =
VP2 3.5 V VP2 2.7 V
VP2 3.5 V VP2 1.9 V
× 100 (%)
AVP4 V Parabola Accuracy4
The output voltage at pin 4 is defined as VP2 4.3 V.
AVP4 =
VP2 3.5 V VP2 4.3 V
VP2 3.5 V VP2 1.9 V
× 100 (%)
AVP5 V Parabola Accuracy5
The output voltage at pin 4 is defined as VP2 5.1 V.
AVP5 =
VP2 3.5 V VP2 5.1 V
VP2 3.5 V VP2 1.9 V
× 100 (%)
GVP1 V Parabola Amplitude1, GVP2 V Parabola Amplitude2, GVP3 V Parabola Amplitude3
Measure the amplitude of parabola waveform at pin 4 when the voltage of pin 5 is 0 V, 2.5 V, and 4 V.
When the voltage of pin 5 is 4 V, the amplitude of parabola waveform is defined as VP70 Hz.