GP1S50/GP1S51V
GP1S52V/GP1S54
s Features
1. High sensing accuracy ( Slilt width : 0.5mm )
2. Both-sides mounting type : GP1S50 (Case height : 10mm )
Either-side mounting type : GP1S51V (Case height : 10mm )
PWB direct mounting type : GP1S52V (Case height : 10mm )
PWB direct mounting type : GP1S54 (Case height : 8mm )
s Outline Dimensions
GP1S50
19.0 ± 0.2
GP1S50/GP1S51V/GP1S52V/GP1S54
General Purpose
Photointerrupter
s Applications
1. OA equipment, such as FDDs, printers,
facsimiles
2. VCRs
GP1S51V
2.0
(Unit : mm )
2 - φ 3.2 ± 0.2
25.0 ± 0.3
12.2 ± 0.3
3.0
+
-
0.2
0.1
2 - C2.0
Slit width (Both sides of
0.5 detector and
emitter )
3
+
-
0.2
0.1
12.2
+
-
0.3
0.3
12.2 ± 0.3
3.0
+
-
0.2
0.1
(Both sides of
detector and
5.0 emitter )
0.5
Slit width
2 - φ 3.2 ± 0.2
4
-
0.4
+
-
0.3
0.1
(9.2)
23
14
Marking : GP1S50
GP1S52V
12.2
+
-
0.3
0.3
3
+
-
0.2
0.1
12.2± 0.3
3.0+-
0.2
0.1
4
-
0.45
+
-
0.3
0.1
(2.54)
* Unspecified tolerances shall be as follows;
Dimensions(d) Tolerance
d<= 6.0 ± 0.1
6.0< d<= 18.0 ± 0.2
18.0< d<= 25.0 ± 0.25
* ( ) : Reference dimensions
(Both sides of
detector and 5.0
emitter ) 0.5
Slit width
C1.0
4
-
0.4
+
-
0.3
0.1
(9.2)
4
1
3
2
GP1S54
4
-
0.45+-
0.3
0.1
(2.54)
12.0
18.0
* Unspecified tolerances shall be as follows ;
Dimensions(d) Tolerance
d<= 6.0 ± 0.1
6.0< d<= 18.0 ± 0.2
* ( ) : Reference dimensions
12.2 ± 0.3
3.0
+
-
0.4
0
(Both sides of
detector and 5.0
emitter ) 0.5
Slit width
C1.0
4
-
0.4
+ 0.3
- 0.1
(9.2)
4
1
3
2
4
-
0.45+-
0.3
0.1
(2.54)
* Unspecified tolerances shall be as follows;
Dimensions(d) Tolerance
d<=6.0 ± 0.1
6.0< d<=18.0 ± 0.2
* ( ) : Reference dimensions
4
-
0.4+-
0.3
0.1
(9.2)
7.5± 0.1
1
2
2 - φ 0.7
43
1.75
2 - R0.3MAX.
4-
0.45
+
-
0.3
0.1
(2.54)
* Unspecified tolerances shall be as follows;
Dimensions(d) Tolerance
d<=6.0 ± 0.1
6.0< d<=18.0 ± 0.2
* ( ) : Reference dimensions
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,