datasheetbank_Logo
Технический паспорт Поисковая и бесплатно техническое описание Скачать

AXX2016 Просмотр технического описания (PDF) - Advanced XTAL Products

Номер в каталоге
Компоненты Описание
Список матч
AXX2016 Datasheet PDF : 2 Pages
1 2
Enclosure drawing
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
2-17
IEC 61178-1
clause ...
4.5
4.6
4.8.2
Solderability
2-20
4.8.3
Resistance to
soldering heat
Shock
2-27
4.8.8
Bump
2-29
4.8.6
Free fall
2-32
4.8.9
Vibration, sinusoidal 2-6
4.8.7
Rapid change of
2-14
temperature
Dry heat
2-2
4.8.5
4.8.11
Damp heat, cyclic 2-30
Cold
2-1
4.8.12
4.8.13
Climatic sequence 1-7
Damp heat, steady 2-3
state
Endurance tests
- ageing
- extended aging
4.8.14
4.8.15
4.9.1
4.9.2
Test conditions
Enclosure styles as in IEC
60122-3, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes,
40g, 6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz -
1 kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper
temperature indicated by
climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower
temperature indicated by
climatic category
Sequence of 4.8.11, 4.8.12 (1st
cycle), 4.8.13, 4.8.12 (5 cycles)
Test Ca, 56 days
30 days @ 85°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXX2016
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: info@axtal.com